Dimensions: [mm]
Recommended Land Pattern: [mm]
Electrical Properties
Properties
Test conditions
Value
22
Unit
V
Tol.
max.
5ꢀ
DC Operating Voltage
(Reverse) Breakdown Voltage
Clamping Voltage
VDC
VBR
1 mA
25.65
35.5
84.5
300
2
V
9,30
IPEAK
VCLAMP
IPEAK
IPEAK
ILEAK
PDISS
PDISS
V
max.
max.
max.
max.
max.
max.
4,70
2,30
(Reverse) Peak Pulse Current
(Forward) Peak Pulse Current 1)
Leakage Current
10/ 1000 µs
A
A
VDC
μA
W
W
Steady State Power Dissipation TA = 50 °C
Power Dissipation 2) 10/ 1000 µs
6.5
1,14 ± 0,38
7,94 ± 0,19
3000
1) 8.3 ms single half-sine wave or equivalent square wave, Duty cycle = 4 pulses per minute
2) Mounted on 8.0 mm x 8.0 mm (0.03 mm thick) Copper Pads to each terminal
Scale - 4:1
6,86 ± 0,25
Schematic:
General Information
Properties
Cathode
Value
It is recommeded that the temperature of the component does not exceed +150°C under worst
case conditions
Operating Temperature
TOP
TS
-65 °C up to +150 °C
-40 °C up to +60 °C
Storage Temperature (in original
packaging)
Test conditions of Electrical Properties: 20°C, 33ꢀ RH if not specified differently
Cathode Band
Anode
Scale - 4:1
Product Marking
Marking
CREATED
CHECKED
GENERAL TOLERANCE
PROJECTION
METHOD
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
PEX
WE
WE
DIN ISO 2768-1m
Max-Eyth-Str. 1
DESCRIPTION
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
WE-TVSP Power TVS Diode
ORDER CODE
www.we-online.com
eiSos@we-online.com
824550221
SIZE
REVISION
STATUS
DATE
BUSINESS UNIT
PAGE
DO-214AB
001.000
Draft
2015-11-06
eiSos
1/7
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.