Two-Hand Control Devices
Zero-Force Touch Buttons
800Z Heavy Industrial
Specifications
Standards
EN574, EN954-1, IEC/EN60947-5-1,
IEC/EN60204-1
Approvals
cULus, C-Tick, and CE marked for all
applicable directives
Power Supply
10-40V DC, 20-30V AC, or 85-264V AC
1.44W, 19.2VA
See Load Life Curves
Power Consumption
Output Ratings
Min. Switched Current/
Voltage
8mA/5V DC
Pollution Degree
Operating Temperature
Humidity
2
-25°C to +55°C (-13° to +131°F)
95% RH
Enclosure Protection
Material
IP66 (NEMA 4/13)
Housing/Guard Valox 357
Description
Gaskets 3.2mm (1/16in) Cork-BUNA-N
The heavy industrial Bulletin 800Z Zero-Force Touch Buttons are
designed for use by machine control systems requiring the use of
two hands. An interlinked sensor surface weaves two capacitive
sensors in offset planes for superior product sensitivity.
Mounting
Conductor Size
Any position
2
0.5-4mm (#12-22AWG)
Te rm ina l P ro te c ti on
Electrical Life
IP 2 X
The 800Z touch buttons are ergonomically designed to require for
ease of operation. No force is required to operate the switch; simply
touching the surface of the switch will initiate an output. The 800Z
can detect the hand though most industrial gloves.
EM-Relay inductive load See Load Life Curves
Vibration
Shock
1.5mm (0.06in) 10-55Hz
100g,11ms half-sine
The contour of the 800Z touch buttons serves two purposes; it
easily conforms to the shape of the hand while helping prevent
defeatability when two-hand control is needed.
Two bi-coloured diagnostic LEDs provide guidance during
operation. The power/fault LED blinks at different rates to provide
diagnostic information to the user. The 800Z detects the presence of
a hand during power-up, noise, and conductive film build-up over
time.
Features
•
•
•
•
•
Zero Force to operate
Ergonomic design
EMC protection
Diagnostic LEDs
Replaceable Relays
Load Life Curves for Heavy Industrial
Relay O utput—Maxim um Load Breaking Capacity
Relay Output—Electrical Endurance
5000
3000
50
AC Resistive Load
10
8
5
1000
250V AC Resistive Load
30V DC Resistive Load
500
3
300
100
AC
Inductive
Load
DC Inductive Load
(pf=0.4)
L/R = 7ms
1
DC
Resistive
Load
0.5
0.3
25V AC Inductive
Load (pf=0.4)
30V DC
50
30
Inductive Load L/R=7ms
0.1
10
0
3
5
10
30 50 100
300 500 1,000
0
1
2
3
4
5
6
7
8
9 10 11
Rated Operating Voltage (V)
Rated Operating Current (A)
11-6