General Purpose Relays
Industrial Relays
Potter & Brumfield
KUEP Series Panel Plug-in Relay
n
n
n
n
n
1 Form X, 2 Form A and 2 Form C contact arrangements
10 amp current rating
Magnetic blow-out
Various mounting options
Indicator lamp available
Typical applications
DC load switching in industrial controls
Approvals
UL E22575; CSA LR15734; CE (KUEP-11 only)
Technical data of approved types on request
Coil Data
Coil voltage range
5 to 125VDC
6 to 240VAC
Class B
Coil insulation system according UL
Contact Data
Coil versions, DC coil
Contact arrangement
Rated voltage
1 form X (NO-DM), 2 form A (NO), 2 form C (CO)
Coil
Rated
voltage
VDC
Operate
voltage
VDC
Coil
resistance
Ω 10ꢀ
Rated coil
power
W
150VDC
10A
code
Rated current
Contact material
AgCdO
300mA, 12VDC
360 ops./hour 360 ops./hour
15/10ms
17ms
AgSnOInO
One pole versions
Min. recommended contact load
Frequency of operation
Operate/releases time max.
Bounce time max.
5
6
5
6
12
24
48
110
125
3.75
4.5
9.0
18.0
36.0
82.5
93.75
21
32
120
1.2
1.125
1.2
1.25
1.3
1.25
1.2
12
24
48
110
125
472
1800
10000
13000
Contact ratings
Type
Load
Cycles
UL 508
Two pole versions
KUEP, 1 form X, AgCdO
10A, 150VDC
1A, 300VDC
2.5 A, 170 VDC, resistive
KUEP, 2 form A, AgCdO
5
6
12
24
48
110
125
5
6
12
24
48
110
125
3.75
4.5
9.0
18.0
36.0
82.5
93.75
14
20
80
320
1250
6720
8680
1.8
1.8
1.8
1.8
1.85
1.8
1.8
100x103
100x103
100x103
5 A, 150 VDC
2.5 A, 170 VDC, resistive
100x103
100x103
All figures are given for coil without preenergization, at ambient temperature +23°C.
KUEP, 2 form C, AgCdO
3 A, 150 VDC
2.5 A, 170 VDC, resistive
10 A, 240 VAC
10 A, 32 VDC
5 FLA, 15 LRA, 250 VAC
1/3 HP, 120 VAC
Coil versions, AC coil
Coil
code
Rated
voltage
VAC
Operate
voltage
VAC
Coil
resistance
Ω 15ꢀ
Rated coil
power
VA
One pole versions
5 A, 120 VAC, tungsten
1/2 HP, 250 VAC
10 FLA, 40 LRA, 125 VAC
3 A, 600 VAC
6
12
24
120
240
6
12
24
120
240
5.1
10.2
20.4
102.0
204.0
6
24
85
2250
9110
2.0
2.0
2.0
2.1
2.1
1/2 HP, 480 VAC
1/2 HP, 600 VAC
1 HP, 480 VAC, 3 phase
Two pole versions
6
12
6
12
5.1
10.2
20.4
102.0
204.0
4.2
18
72
1700
7200
2.8
2.8
2.8
2.9
2.9
KUEP, 1 form X, AgSnOInO
10A, 150VDC, resistive
KUEP, 2 form A, AgSnOInO
5 A, 150 VDC, resistive
KUEP, 2 form C, AgSnOInO
3 A, 150 VDC, resistive
Mechanical endurance
30x103
100x103
100x103
24
120
240
24
120
240
All figures are given for coil without preenergization, at ambient temperature +23°C.
10x106 ops.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
1200Vrms
2200Vrms
2200Vrms
100MΩ
1
12-2016, Rev. 1216
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company