描述
Variable Capacitance Accelerometer

7596-100 数据手册

 浏览型号7596-100的Datasheet PDF文件第2页 
ENDEVCO  
MODEL  
7596A  
Variable Capacitance Accelerometer  
Model 7596A  
Economical and Rugged  
2 to 100 g Full Scale  
DC Response  
Gas Damped Sensor  
Mechanical Over-range Stops  
DESCRIPTION  
Actual size  
The ENDEVCO Model 7596A VALULINE  
accelerometer family is a low cost solution to low-level,  
low frequency measurements. Applications include labora-  
tory measurements, ground transportation studies and mea-  
surements where the accelerometer will be subjected to  
high shock levels (up to 10 000 gs, see specifications).  
The 7596A is ideal for modal studies on large structures.  
Gas damping and internal overange stops enable the  
anisotropically etched silicon microsensors to withstand  
high shocks and acceleration loads. The use of gas damp-  
ing, in the sensor, results in very small-induced changes of  
frequency response. The patented sensor design ensures  
immediate stability making the unit ready to take accurate  
DC or dynamic data within one millisecond!  
The 7596A can operate from 8.5Vdc to 30Vdc and pro-  
vide a high level, low impedance output. The output is  
high enough to drive most laboratory instruments, tape  
recorders and data acquisition systems without amplifica-  
tion or signal conditioning. The output can be fed into  
either a differential or single-ended amplifier or standard  
bridge electronics with 10Vdc excitation.  
ENDEVCO Model 136 Three-Channel System, Model  
4430A or OASIS Computer-Controlled System are  
recommended signal conditioners.  
SPECIFICATIONS  
PERFORMANCE CHARACTERISTICS: All values are typical at +75°F (+24°C) and 15 Vdc excitation unless otherwise stated. Calibration data, traceable to  
the National Institute of Standards, (NIST), is supplied.  
Units  
g pk  
mV/g  
Hz  
7596-2  
±2  
-10  
±10  
-30  
±30  
-50  
±50  
-100  
±100  
20 ±2  
0 to 1000  
6000  
±1  
±2  
1
±200  
0.6  
RANGE  
SENSITIVITY (at 100 Hz) [1] [2]  
FREQUENCY RESPONSE (± 5%)  
MOUNTED RESONANCE FREQUENCY  
NON-LINEARITY AND HYSTERESIS [3]  
1000 ±100  
0 to 15  
1300  
±0.20  
±0.50  
1
200 ±20  
0 to 500  
3000  
±0.20  
±0.50  
1
66 ±8  
0 to 800  
5500  
±0.20  
±0.50  
1
40 ±4  
0 to 1000  
5500  
±0.2  
±0.5  
1
Hz  
% FSO Typ  
% FSO (Max)  
% Typ  
mV Max  
TRANSVERSE SENSITIVITY [4]  
ZERO MEASURAND OUTPUT [2]  
DAMPING RATIO  
±200  
3.0  
±200  
0.7  
±200  
0.7  
±200  
0.6  
DAMPING RATIO CHANGE  
From -65°F to +250°F ( -55°C to +121°C)  
%/°F  
%/°C  
+0.04  
+0.08  
+0.04  
+0.08  
+0.04  
+0.08  
+0.04  
+0.08  
+0.04  
+0.08  
APPLIES TO CALIFORNIA FACILITY  

与7596-100相关器件

型号 品牌 获取价格 描述 数据表
7596-2 ETC

获取价格

Variable Capacitance Accelerometer
7596-30 ETC

获取价格

Variable Capacitance Accelerometer
7596-50 ETC

获取价格

Variable Capacitance Accelerometer
75967 FCI-CONNECTOR

获取价格

C.T.W MALE PIN
75967-011 AMPHENOL

获取价格

Connector Accessory
75967-011LF AMPHENOL

获取价格

Connector Accessory
75967-018 AMPHENOL

获取价格

Connector Accessory,
75967-028 AMPHENOL

获取价格

Connector Accessory,
75967-092LF AMPHENOL

获取价格

Connector Accessory
75967-111LF AMPHENOL

获取价格

Connector Accessory