Absolute Maximum Ratings(Note 1)
Recommended Operating
Conditions (Note 2)
Supply Voltage (VCC
)
−0.5V to +7.0V
DC Input Diode Current (IIK
VI = −0.5V
)
Supply Voltage (VCC
)
2.0V to 3.6V
0V to VCC
−20 mA
+20 mA
Input Voltage (VI)
VI = VCC + 0.5V
Output Voltage (VO)
0V to VCC
DC Input Voltage (VI)
−0.5V to VCC + 0.5V
Operating Temperature (TA)
−40°C to +85°C
DC Output Diode Current (IOK
)
Minimum Input Edge Rate ∆V/∆t
V
V
O = −0.5V
−20 mA
+20 mA
V
IN from 0.8V to 2.0V
O = VCC + 0.5V
VCC @ 3.0V
125 mV/ns
DC Output Voltage (VO)
DC Output Source
−0.5V to VCC + 0.5V
or Sink Current (IO)
±50 mA
Note 1: The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The “Recommended Operating Conditions” table will define the conditions
for actual device operation.
DC VCC or Ground Current
(ICC or IGND
)
±400 mA
Storage Temperature (TSTG
DC Latch-Up Source or
Sink Current
)
−65°C to +150°C
Note 2: Unused inputs must be held HIGH or LOW. They may not float.
±300 mA
DC Electrical Characteristics
VCC
T
A = +25°C
TA = −40°C to +85°C
Symbol
VIH
Parameter
Units
Conditions
(V)
Typ
Guaranteed Limits
Minimum High Level
Input Voltage
V
OUT = 0.1V
or VCC − 0.1V
OUT = 0.1V
or VCC − 0.1V
OUT = −50 µA
IN = VIL or VIH (Note 3)
3.0
1.5
2.0
2.0
V
VIL
Maximum Low Level
Input Voltage
V
3.0
3.0
3.0
3.0
3.0
1.5
0.8
2.9
0.8
2.9
V
V
V
V
V
VOH
Minimum High Level
Output Voltage
2.99
I
V
2.58
0.1
2.48
0.1
I
I
OH = −12 mA
OUT = 50 µA
VOL
Maximum Low Level
Output Voltage
0.002
V
IN = VIL or VIH (Note 3)
OL = 12 mA
VI = VCC, GND
0.36
±0.1
0.44
I
IIN
Maximum Input Leakage Current
Minimum Dynamic (Note 4)
Output Current
3.6
3.6
3.6
±1.0
36
µA
mA
mA
IOLD
IOHD
ICC
V
V
V
OLD = 0.8V Max (Note 5)
OHD = 2.0V Min (Note 5)
IN = VCC
−25
Maximum Quiescent
Supply Current
3.6
4.0
40.0
µA
or GND
IOZ
Maximum 3-STATE
Leakage Current
VI (OE) = VIL, VIH
VI = VCC, GND
3.6
±0.25
±2.5
µA
VO = VCC, GND
VOLP
VOLV
VIHD
VILD
Quiet Output
Maximum Dynamic VOL
3.3
3.3
3.3
3.3
0.4
−0.4
1.7
0.8
−0.8
2.0
V
V
V
V
(Note 6)(Note 7)
(Note 6)(Note 7)
(Note 6)(Note 8)
(Note 6)(Note 8)
Quiet Output
Minimum Dynamic VOL
Minimum High Level
Dynamic Input Voltage
Maximum Low Level
Dynamic Input Voltage
1.7
0.8
Note 3: All outputs loaded thresholds on input associated with output under test.
Note 4: Maximum test duration 2.0 ms, one output loaded at a time.
Note 5: Incident wave switching on transmission lines with impedances as low as 75Ω for commercial temperature range is guaranteed for 74LVQ.
Note 6: Worst case package.
Note 7: Max number of outputs defined as (n). Data inputs are driven 0V to 3.3V; one output at GND.
Note 8: Max number of Data Inputs (n) switching. (n − 1) inputs switching 0V to 3.3V. Input-under-test switching: 3.3V to threshold (VILD), 0V to threshold
(VIHD), f = 1 MHz.
www.fairchildsemi.com
2