Nexperia
74HC14-Q100; 74HCT14-Q100
Hex inverting Schmitt trigger
8. Limiting values
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
Max
+7
Unit
V
VCC
IIK
supply voltage
-0.5
input clamping current
output clamping current
output current
VI < -0.5 V or VI > VCC + 0.5 V
VO < -0.5 V or VO > VCC + 0.5 V
-0.5 V < VO < VCC + 0.5 V
[1]
[1]
-
±20
±20
±25
50
mA
mA
mA
mA
mA
°C
IOK
IO
-
-
ICC
IGND
Tstg
Ptot
supply current
-
ground current
-50
-65
-
-
storage temperature
total power dissipation
+150
500
[2]
mW
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For SOT108-1 (SO14) package: Ptot derates linearly with 10.1 mW/K above 100 °C.
For SOT402-1 (TSSOP14) package: Ptot derates linearly with 7.3 mW/K above 81 °C.
For SOT762-1 (DHVQFN14) package: Ptot derates linearly with 9.6 mW/K above 98 °C.
9. Recommended operating conditions
Table 5. Recommended operating conditions
Voltages are referenced to GND (ground = 0 V)
Symbol Parameter
Conditions
74HC14-Q100
74HCT14-Q100
Unit
Min
2.0
0
Typ
5.0
-
Max
Min
4.5
0
Typ
5.0
-
Max
5.5
VCC
VI
supply voltage
input voltage
6.0
VCC
VCC
+125
V
V
V
VCC
VCC
VO
output voltage
ambient temperature
0
-
0
-
Tamb
-40
+25
-40
+25
+125 °C
©
74HC_HCT14_Q100
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2021. All rights reserved
Product data sheet
Rev. 7 — 13 August 2021
4 / 17