Nexperia
74HC14-Q100; 74HCT14-Q100
Hex inverting Schmitt trigger
10. Static characteristics
Table 6. Static characteristics
At recommended operating conditions; voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Tamb = 25 °C
Tamb = -40 °C Tamb = -40 °C Unit
to +85 °C to +125 °C
Min
Typ
Max
Min Max
Min
Max
74HC14-Q100
VOH
HIGH-level
VI = VT+ or VT-
output voltage
IO = -20 μA; VCC = 2.0 V
IO = -20 μA; VCC = 4.5 V
IO = -20 μA; VCC = 6.0 V
IO = -4.0 mA; VCC = 4.5 V
IO = -5.2 mA; VCC = 6.0 V
VI = VT+ or VT-
1.9
4.4
2.0
4.5
-
-
-
-
-
1.9
4.4
-
-
-
-
-
1.9
4.4
5.9
3.7
5.2
-
-
-
-
-
V
V
V
V
V
5.9
6.0
5.9
3.98
5.48
4.32
5.81
3.84
5.34
VOL
LOW-level
output voltage
IO = 20 μA; VCC = 2.0 V
IO = 20 μA; VCC = 4.5 V
IO = 20 μA; VCC = 6.0 V
IO = 4.0 mA; VCC = 4.5 V
IO = 5.2 mA; VCC = 6.0 V
-
-
-
-
-
-
0
0
0.1
0.1
-
-
-
-
-
-
0.1
0.1
-
-
-
-
-
-
0.1
0.1
0.1
0.4
0.4
V
V
V
V
V
0
0.1
0.1
0.15
0.16
-
0.26
0.26
±0.1
0.33
0.33
±1.0
II
input leakage VI = VCC or GND; VCC = 6.0 V
current
±1.0 μA
ICC
CI
supply current VI = VCC or GND; IO = 0 A;
VCC = 6.0 V
-
-
-
2.0
-
-
-
20
-
-
-
40
-
μA
pF
input
3.5
capacitance
74HCT14-Q100
VOH HIGH-level
VI = VT+ or VT-; VCC = 4.5 V
IO = -20 μA
output voltage
4.4
4.5
-
-
4.4
-
-
4.4
3.7
-
-
V
V
IO = -4.0 mA
3.98
4.32
3.84
VOL
LOW-level
output voltage
VI = VT+ or VT-; VCC = 4.5 V
IO = 20 μA;
-
-
-
0
0.15
-
0.1
-
-
-
0.1
-
-
-
0.1
0.4
V
V
IO = 4.0 mA;
0.26
±0.1
0.33
±1.0
II
input leakage VI = VCC or GND; VCC = 5.5 V
current
±1.0 μA
40 μA
147 μA
ICC
ΔICC
supply current VI = VCC or GND; IO = 0 A;
VCC = 5.5 V
-
-
-
2.0
-
-
20
-
-
additional
per input pin; VI = VCC - 2.1 V;
30
108
135
supply current other pins at VCC or GND;
IO = 0 A; VCC = 4.5 V to 5.5 V
CI
input
-
3.5
-
-
-
-
-
pF
capacitance
©
74HC_HCT14_Q100
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2021. All rights reserved
Product data sheet
Rev. 7 — 13 August 2021