Nexperia
74AUP1T14
Low-power inverter with voltage-level translator
7. Functional description
Table 4. Function table
H = HIGH voltage level; L = LOW voltage level.
Input
Output
A
L
Y
H
L
H
8. Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min
-0.5
-50
-0.5
-50
-0.5
-
Max
+4.6
-
Unit
V
VCC
IIK
supply voltage
input clamping current
input voltage
VI < 0 V
mA
V
VI
[1]
[1]
+4.6
-
IOK
VO
IO
output clamping current
output voltage
VO < 0 V
mA
V
Active mode and Power-down mode
VO = 0 V to VCC
+4.6
±20
50
output current
mA
mA
mA
°C
ICC
IGND
Tstg
Ptot
supply current
-
ground current
-50
-65
-
-
storage temperature
total power dissipation
+150
250
Tamb = -40 °C to +125 °C
[2]
mW
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For SOT353-1 (TSSOP5) package: Ptot derates linearly with 3.3 mW/K above 74 °C.
For SOT1226-3 (X2SON5) package: Ptot derates linearly with 3.0 mW/K above 67 °C.
9. Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter
Conditions
Min
2.3
0
Max
3.6
Unit
V
VCC
VI
supply voltage
input voltage
output voltage
3.6
V
VO
Active mode
0
VCC
3.6
V
Power-down mode; VCC = 0 V
0
V
Tamb
ambient temperature
-40
+125
°C
©
74AUP1T14
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2022. All rights reserved
Product data sheet
Rev. 3 — 25 January 2022