Nexperia
74AUP1G08-Q100
Low-power 2-input AND gate
Symbol Parameter
Conditions
Min
Typ
Max
Unit
VOH
HIGH-level output voltage VI = VIH or VIL
IO = -20 μA; VCC = 0.8 V to 3.6 V
VCC - 0.11
0.6 × VCC
0.93
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V
V
V
V
V
V
V
V
IO = -1.1 mA; VCC = 1.1 V
IO = -1.7 mA; VCC = 1.4 V
IO = -1.9 mA; VCC = 1.65 V
IO = -2.3 mA; VCC = 2.3 V
IO = -3.1 mA; VCC = 2.3 V
IO = -2.7 mA; VCC = 3.0 V
IO = -4.0 mA; VCC = 3.0 V
1.17
1.77
1.67
2.40
2.30
VOL
LOW-level output voltage
VI = VIH or VIL
IO = 20 μA; VCC = 0.8 V to 3.6 V
IO = 1.1 mA; VCC = 1.1 V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.11
0.33 × VCC
0.41
V
V
IO = 1.7 mA; VCC = 1.4 V
V
IO = 1.9 mA; VCC = 1.65 V
IO = 2.3 mA; VCC = 2.3 V
0.39
V
0.36
V
IO = 3.1 mA; VCC = 2.3 V
0.50
V
IO = 2.7 mA; VCC = 3.0 V
0.36
V
IO = 4.0 mA; VCC = 3.0 V
0.50
V
II
input leakage current
VI = GND to 3.6 V; VCC = 0 V to 3.6 V
±0.75
±0.75
±0.75
μA
μA
μA
IOFF
power-off leakage current VI or VO = 0 V to 3.6 V; VCC = 0 V
ΔIOFF additional power-off
leakage current
VI or VO = 0 V to 3.6 V;
VCC = 0 V to 0.2 V
ICC
supply current
VI = GND or VCC; IO = 0 A;
VCC = 0.8 V to 3.6 V
-
-
-
-
1.4
75
μA
μA
ΔICC
additional supply current
VI = VCC - 0.6 V; IO = 0 A; VCC = 3.3 V [1]
[1] One input at VCC - 0.6 V, other input at VCC or GND.
11. Dynamic characteristics
Table 8. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); for test circuit see Fig. 7
Symbol
Parameter
Conditions
Min
Typ [1]
Max
Unit
Tamb = 25 °C; CL = 5 pF
tpd
propagation delay
A, B to Y; see Fig. 6
VCC = 0.8 V
[2]
-
17.0
-
ns
ns
ns
ns
ns
ns
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
2.6
1.6
1.3
1.1
1.0
5.1
3.7
3.0
2.4
2.2
10.8
6.5
5.2
4.0
3.5
©
74AUP1G08_Q100
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2019. All rights reserved
Product data sheet
Rev. 2 — 28 January 2019