7. Functional description
Table 4. Function table
H = HIGH voltage level; L = LOW voltage level.
Input
Output
A
L
B
L
Y
L
L
L
H
L
H
L
H
H
H
8. Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol
VCC
IIK
Parameter
Conditions
Min
-0.5
-50
-0.5
-50
-0.5
-
Max
+4.6
-
Unit
V
supply voltage
input clamping current
input voltage
VI < 0 V
mA
V
VI
[1]
+4.6
-
IOK
output clamping current
output voltage
VO < 0 V
mA
V
VO
Active mode and Power-down mode [1]
VO = 0 V to VCC
+4.6
±20
+50
-
IO
output current
mA
mA
mA
°C
ICC
supply current
-
IGND
Tstg
Ptot
ground current
-50
-65
-
storage temperature
total power dissipation
+150
250
Tamb = -40 °C to +125 °C
[2]
mW
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] For TSSOP5 packages: above 87.5 °C the value of Ptot derates linearly with 4.0 mW/K.
For XSON6 packages: above 118 °C the value of Ptot derates linearly with 7.8 mW/K.
9. Recommended operating conditions
Table 6. Recommended operating conditions
Symbol
VCC
VI
Parameter
Conditions
Min
0.8
0
Max Unit
supply voltage
input voltage
output voltage
3.6
3.6
VCC
3.6
V
V
V
V
VO
Active mode
0
Power-down mode; VCC = 0 V
0
Tamb
ambient temperature
-40
0
+125 °C
Δt/ΔV
input transition rise and fall rate VCC = 0.8 V to 3.6 V
200 ns/V
©