74AUP1G06-Q100
Nexperia
Low-power inverter with open-drain output
Table 8.
Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 6.
Symbol Parameter
Conditions
25 C
40 C to +125 C
Unit
Min Typ[1] Max
Min
Max
Max
(85 C) (125 C)
CL = 15 pF
[2]
[2]
[3]
tpd
propagation delay A to Y; see Figure 5
VCC = 0.8 V
-
18.8
6.4
4.6
4.5
3.5
4.0
-
-
-
-
ns
ns
ns
ns
ns
ns
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
3.2
2.6
2.3
2.1
2.0
12.2
7.7
6.6
4.6
6.0
2.9
2.3
2.1
1.7
1.5
15.2
9.4
7.3
5.1
6.5
17.0
10.0
8.1
5.7
7.2
CL = 30 pF
tpd propagation delay A to Y; see Figure 5
VCC = 0.8 V
-
27.8
9.3
6.8
6.8
5.3
6.5
-
-
-
-
ns
ns
ns
ns
ns
ns
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
4.4
3.6
3.2
2.9
2.9
16.5
10.1
10.7
7.2
3.9
3.2
2.9
2.6
2.5
19.3
12.0
11.0
7.8
21.3
13.2
12.1
8.6
10.5
10.8
11.9
CL = 5 pF, 10 pF, 15 pF and 30 pF
CPD power dissipation fi = 1 MHz; VI = GND to VCC
capacitance
VCC = 0.8 V
-
-
-
-
-
-
0.5
0.6
0.7
0.7
1.0
1.2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
pF
pF
pF
pF
pF
pF
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
[1] All typical values are measured at nominal VCC
[2] tpd is the same as tPZL and tPLZ
[3] PD is used to determine the dynamic power dissipation (PD in W).
.
.
C
PD = CPD VCC2 fi N where:
fi = input frequency in MHz;
VCC = supply voltage in V;
N = number of inputs switching.
74AUP1G06_Q100
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 1 — 31 January 2013
7 of 13