5秒后页面跳转
7024ABB PDF预览

7024ABB

更新时间: 2024-09-15 06:31:11
品牌 Logo 应用领域
泰科 - TE 继电器电子
页数 文件大小 规格书
6页 360K
描述
Industrial Electropneumatic Timing Relay

7024ABB 数据手册

 浏览型号7024ABB的Datasheet PDF文件第2页浏览型号7024ABB的Datasheet PDF文件第3页浏览型号7024ABB的Datasheet PDF文件第4页浏览型号7024ABB的Datasheet PDF文件第5页浏览型号7024ABB的Datasheet PDF文件第6页 
Catalog 1308242  
Issued 3-03 (PDF Rev. 10-07)  
AGASTAT  
7000 series  
Industrial Electropneumatic  
Timing Relay  
File E15631  
File LR29186  
Note:7032 types and certain models with accessories are not agency approved.  
Users should thoroughly review the technical data before selecting a product  
part number. It is recommended that users also seek out the pertinent  
approvals files of the agencies/laboratories and review them to confirm the  
product meets the requirements for a given application.  
Consult factory for ordering information.  
Design Features  
On-delay model 7012 (delay on pickup)  
• Available in on-delay, true off-delay, and on/off-delay.  
Applying continuous voltage to the coil  
(L1-L2) starts a time delay lasting for  
the preset time. During this period the  
normally closed contacts (3-5 and 4-6)  
remain closed. At the end of the delay  
period the normally closed contacts  
break and the normally open contacts  
(1-5 and 2-6) make. The contacts re-  
main in this transferred position until  
the coil is deenergized, at which time  
the switch instantaneously returns to  
its original position.  
De-energizing the coil, either during  
or after the delay period, will recycle  
the unit within 50 msec.  
It will then provide a full delay period  
upon re-energization, regardless of  
how often the coil voltage is interrupt-  
ed before the unit has been permitted  
to "time-out" to its full delay setting.  
Timing from 0.1 seconds to 60 minutes, in linear increments.  
• Oversize time-calibrated adjustment knobs, serrated with high-resolution  
markings visible from all angles makes the timer easy to set timers.  
• Inherent transient immunity.  
• Standard voltages from 6-550VAC and 12-550VDC (special voltages available.)  
• Available in 2-pole or 4-pole models.  
• Numerous enclosure options: explosion proof, dust tight, watertight,  
hermetically-sealed, NEMA 1.  
• Auxiliary timed and instantaneous switches can be added for greater switching  
flexibility.  
• Many mounting options: Surface mount, Panel mount, Octal plug-in mounting.  
• Options: quick-connect terminals, dial stops, and transient protection module.  
• Easy-to-reach screw terminals, all on the face of the unit, clearly identified.  
• Modular assembly - timing head, coil assembly and switchblock are all  
individual modules, with switches field-replaceable.  
Design & Construction  
There are three main components of Series 7000 Timing Relays:  
Calibrated Timing Head uses no needle valve, recirculates air under  
controlled pressure through a variable orifice to provide linearly adjustable  
timing. Patented design provides instant recycling, easy adjustment and long  
service life under severe operating conditions.  
Off-delay model 7022 (delay on dropout)  
Applying voltage to the coil (for at  
least 50 msec) will instantaneously  
transfer the switch, breaking the nor-  
mally closed contacts (1-5 and 2-6),  
and making the normally open  
contacts (3-5 and 4-6). Contacts  
remain in this transferred position as  
long as the coil is energized. The  
time delay begins immediately upon  
de-energization. At the end of the de-  
lay period the switch returns to its  
normal position.  
Re-energizing the coil during the  
delay period will immediately return  
the timing mechanism to a point  
where it will provide a full delay  
period upon subsequent de-  
Precision-Wound Potted Coil module supplies the initial motive force  
with minimum current drain. Total sealing without external leads eliminates  
moisture problems, gives maximum insulation value.  
Snap-Action Switch Assembly  
- custom-designed over-center  
mechanism provides greater contact pressure up to transfer time for  
positive, no flutter action. Standard switches are DPDT arrangement, with  
flexible beryllium copper blades and silver-cadmium oxide contacts. Special  
"timing-duty" design assures positive wiping action, sustained contact pres-  
sure and greater heat dissipation during long delay periods.  
Each of these subassemblies forms a self-contained module which is  
then assembled at the factory with the other two to afford a wide choice of  
operating types, coil voltages, and timing ranges.  
The squared design with front terminals and rear mounting permits the  
grouping of Series 7000 units side-by-side in minimum panel space.  
Auxiliary switches may be added in the base of the unit, without affecting  
the overall width or depth.  
energization. The switch remains in  
the transferred position.  
Operation  
Two basic operating types are available.  
To increase the versatility of the basic timer models, auxiliary switches may  
be added to either on-delay or off-delay types. They switch additional circuits,  
provide two-step timing action, or furnish electrical interlock for sustained coil  
energization from a momentary impulse, depending on the type selected and  
its adjustment. Because of their simple attachment and adjustment features,  
they can be installed at the factory or in the field, by any competent mechanic.  
All auxiliary switches are SPDT with UL listings of 10A @ 125, 250, or 480  
VAC. A maximum of one Code T or two Code L auxiliary switches may be  
added to each relay. The L or LL switch is available with on-delay relays only.  
The T switch is available with both the on-delay and off-delay relays.  
Auxiliary Switch Options for On-Delay  
“On-Delay” models provide a delay period on energization, at the end of  
which the switch transfers the load from one set of contacts to another. De-  
energizing the unit during the delay period immediately recycles the unit,  
readying it for another full delay period on re-energization.  
In "Off-Delay" models the switch transfers the load immediately upon  
energization, and the delay period does not begin until the unit is de-  
energized. At the end of the delay period the switch returns to its original po-  
sition. Re-energizing the unit during the delay period immediately resets the  
timing, readying it for another full delay period on de-energization. No power  
is required during the timing period.  
In addition to these basic operating types, "Double-Head" models offer  
sequential delays on pull-in and drop-out in one unit. With the addition of  
auxiliary switches the basic models provide two-step timing, pulse actuation  
for interlock circuits, or added circuit capacity.  
Instant Transfer (Auxiliary Switch Code L,  
maximum of 2 per relay.)  
1. Energizing coil begins time delay and transfers auxiliary switch.  
2. Main switch transfers after total preset delay.  
3. De-energizing coil resets both switches instantly.  
Auxiliary switch is nonadjustable.  
NOTE: Seismic & radiation tested E7000 models are available.  
Consult factory for detailed information.  
Two-Step Timing (Auxiliary Switch Code T,  
maximum of 1 per relay.)  
Dimensions are shown for  
reference purposes only.  
Dimensions are in inches over  
(millimeters) unless otherwise  
specified.  
Specifications and availability  
subject to change.  
www.tycoelectronics.com  
Technical support:  
Refer to inside back cover.  
1248  

与7024ABB相关器件

型号 品牌 获取价格 描述 数据表
7024ABGZ TE

获取价格

Industrial Electropneumatic Timing Relay
7024ACA1 TE

获取价格

Industrial Electropneumatic Timing Relay
7024ACB TE

获取价格

Industrial Electropneumatic Timing Relay
7024ACGZ TE

获取价格

Industrial Electropneumatic Timing Relay
7024BAA1 TE

获取价格

Industrial Electropneumatic Timing Relay
7024BAB TE

获取价格

Industrial Electropneumatic Timing Relay
7024BAGZ TE

获取价格

Industrial Electropneumatic Timing Relay
7024BBA1 TE

获取价格

Industrial Electropneumatic Timing Relay
7024BBB TE

获取价格

Industrial Electropneumatic Timing Relay
7024BBGZ TE

获取价格

Industrial Electropneumatic Timing Relay