General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RZ
n
n
n
n
n
1 pole 12/16 A, 1 form C (CO) or 1 form A (NO) contact
DC coil 400 mW
5kV/10mm coil-contact, reinforced insulation
Ambient temperature 85°C
Product in accordance to IEC 60335-1
Typical applications
Household appliances, boiler control, timers, garage door control, POS
automation
F0305-A
Z
Approvals
VDE Cert. No. 40023970, UL E214025, CQC 12002066685
Technical data of approved types on request
Contact ratings for RZ reinforced flux proof version
Type
IEC 61810
Contact
Load
Cycles
Contact Data
12A
16A
Contact arrangement
Rated voltage
1 form C (CO) or 1 form A (NO)
RZ03-1C3-D...-R
RZ03-1C3-D...-R
RZ01-1C3-D...-R
RZ01-1C3-D...-R
RZ03-1C4-D...-R
RZ03-1C4-D...-R
RZ02/3-1C4-D...-R
RZ02/3-1C4-D...-R
UL 508
RZ03-1C3-D...-R
RZ03-1C3-D...-R
RZ01-1C3-D...-R
RZ01-1C3-D...-R
RZ03-1C4-D...-R
RZ03-1C4-D...-R
RZ02/3-1C4-D...-R
RZ02/3-1C4-D...-R
A (NO)
C (CO)
A (NO)
C (CO)
A (NO)
C (CO)
A (NO)
C (CO)
16A, 250VAC, 85°C
16A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
16A, 250VAC, 85°C
16A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
30x103
6x103
250VAC
400VAC
Max. switching voltage
Rated current
Limiting making current (form A contact)
max. 4s, duty factor 10%
max. 20ms (incandescent lamp); AgSnO2
Breaking capacity max.
30x103
6x103
12A
16A
30x103
6x103
30A
80A
50x103
20x103
3000VA
4000VA
Contact material
AgNi 90/10 or AgSnO2
360/72000h-1
8/6ms
Frequency of operation, with/without load
Operate/release time max.
Bounce time max., form A/form B
A (NO)
C (CO)
A (NO)
C (CO)
A (NO)
C (CO)
A (NO)
C (CO)
16A, 277VAC, 85°C
16A, 277VAC, 85°C
12A, 277VAC, 85°C
12A, 277VAC, 85°C
16A, 277VAC, 85°C
16A, 277VAC, 85°C
12A, 277VAC, 85°C
12A, 277VAC, 85°C
30x103
6x103
4/10ms
30x103
6x103
Contact ratings for standard version
30x103
6x103
Type
Contact
Load
Cycles
IEC 61810
RZ03-1A4
RZ03-1C4
RZ01-1A3
RZ01-1A4
RZ01-1C4
RZ01/3-1A4
RZ0H-1A4
RZ0H-1A4
RZ0H-1A4
UL 508
RZ03-1A.
RZ03-1A4
RZ01-1A3
RZ03-1.4
RZ03-1.4
RZ03-1.4
RZ03-1A.
50x103
20x103
A (NO)
C (CO)
A (NO)
A (NO)
C (CO)
A (NO)
A (NO)
A (NO)
A (NO)
16A, 250VAC, 85°C
16A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
10A, 250VAC, 85°C
12A, 250VAC, 85°C
16A, 250VAC, 85°C
18A, 250VAC, 85°C
50x103
10x103
100x103
50x103
30x103
150x103
150x103
50x103
30x103
Mechanical endurance
>10x106 operations
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
16A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
B300, R300, 85°C
12A, 250VAC, 85°C
1/2hp, 125VAC, 85°C
1hp, 277VAC, 85°C
50x103
150x103
50x103
6x103
100x103
6x103
30x103
1)
1) valid for standard version
1
02-2016, Rev. 0216
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.