CUSTOMER DRAWING
Product Dimensions
Cable Dimensions
Product
Name
L
max
øA
min
øB
min
øD
max
øE
min
J±0.5
(J±0.02)
8
M±0.5
(M±0.02)
9
29.75
(1.170)
10.80
(0.425)
11.65
(0.460)
11.43
(0.450)
5.70
D-104-00
(0.225)
(0.315)
(0.355)
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Sn63 per ANSI-J-STD-006.
FLUX:
TYPE ROL1 per ANSI-J-STD-004.
3. MELTABLE RINGS: Thermally stabilized thermoplastic. Color: natural.
APPLICATION
1. This part is designed to provide an environment protected shield termination on cables, rated for 125°C minimum, meeting the
dimensional criteria listed, having tin or silver plated copper shields.
2. Install using Tyco Electronics approved convection or infrared tools in accordance with Tyco Electronics assembly procedure
RCPS-100-70.
3. Assemblies will meet requirements of Tyco Electronics specification RT-1404 and National Aerospace Standard NAS-1747.
4. Temperature range: -55°C to +150°C.
For best results, prepare the cable as shown:
TITLE:
Tyco Electronics
300 Constitution Dr
Menlo Park, CA
94025, U.S.A.
SOLDERSLEEVE SHIELD TERMINATOR
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets]
DOCUMENT NO.:
Raychem
Devices
D-104-00
TOLERANCES:
0.00 N/A
0.0 N/A
ANGLES: N/A
Tyco Electronics reserves the right to
amend this drawing at any time. Users
should evaluate the suitability of the
product for their application.
REV:
DATE:
ROUGHNESS
IN MICRON
A
22-Aug-07
0 N/A
DRAWN BY:
CAGE CODE:
REPLACES:
ECO NUMBER:
SCALE:
SIZE:
SHEET:
P.TALLY
06090
D981826
07-019646
NTS
A
1 of 1
If this document is printed it becomes uncontrolled. Check for the latest revision
© 2007 Tyco Electronics Corporation. All rights reserved