描述
Field Network Modules 61-UNIT Series

61F-041-R 数据手册

 浏览型号61F-041-R的Datasheet PDF文件第2页浏览型号61F-041-R的Datasheet PDF文件第3页 
MODEL: 61F  
Field Network Modules 61-UNIT Series  
[4] OPTIONS  
blank: none  
/Q: With options (specify the specification)  
ANALOG I/O MODULE  
(Fuji Electric T-Link use)  
Functions & Features  
SPECIFICATIONS OF OPTION: Q  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
• Interfacing analog I/O signals from/to Mini-M or Pico-M  
modules with T-LINK  
• Saving power and I/O wiring inside an instrumentation  
panel  
/C02: Polyurethane coating  
/C03: Rubber coating  
RELATED PRODUCTS  
• Installation Base (model: M2BS2)  
• Installation Base (model: M8BS2)  
50  
(1.97)  
100  
(3.94)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
12  
4
5
0
6
9
7
12  
4
5
0
6
9
7
Connection  
T-Link: Euro type connector terminal (applicable wire  
115 (4.53)  
mm (inch)  
size: 0.2 to 2.5 mm , stripped length 7 mm)  
2
I/O: Via Installation Base (model: MxBS2)  
Power input: Via Installation Base (model: MxBS2)  
Housing material: Flame-resistant resin (black)  
Isolation: I/O or T-Link to power  
MODEL: 61F-[1][2]-[3][4]  
Power indicator: Green LED turns on with power supplied.  
ORDERING INFORMATION  
• Code number: 61F-[1][2]-[3][4]  
Specify a code from below for each [1] through [4].  
(e.g. 61F-161-K/Q)  
T-Link SPECIFICATIONS  
Configuration: Multi-drop  
Communication: Half-duplex  
Baud rate: 500 kbps  
• Specify the specification for option code /Q  
(e.g. /C01)  
Transmission media/distance:  
KPEV-SB 0.75 mm  
2
× 1 pair, 700 m  
× 1 pair, 1000 m  
T-KPEV-SB, 1.25 mm  
2
[1] NO. OF CHANNELS  
04: 4 points  
Station No.: Rotary switch; 00 - 99  
(Factory default setting: 00)  
08: 8 points  
L RUN indicator: Red LED ON at normal communication  
L ERR. indicator: Red LED ON/blinking at communication  
abnormality  
16: 16 points  
[2] I/O TYPE  
1: Input  
L I/O indicator: Red LED blinking at normal I/O  
L COM indicator: RED LED blinking at T-Link normal  
communication  
2: Output  
NUMBER OF CONNECTABLE UNITS WITH T-LINK  
Up to a maximum of 32 T-LINK devices can be connected in  
a single T-LINK system. There is a limit of 100 words in  
processor memory. Make sure that the configured word  
area to be occupied does not exceed the 100-word range.  
(According to the Fuji Electric MICREX-F Users Manual)  
It is necessary to consider these criteria when connecting to  
this device.  
[3] POWER INPUT  
AC Power  
K: 85 – 132 V AC  
(Operational voltage range 85 – 132 V, 47 – 66 Hz)  
DC Power  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
(Specify power suffix code R (24 V DC) when the UNIT is to be  
combined with the M8BS2.)  
The below describes the number of words occupied per  
device by number of modules.  
61F SPECIFICATIONS  
ES-6635 Rev.2 Page 1/3  
http://www.m-system.co.jp/  

与61F-041-R相关器件

型号 品牌 获取价格 描述 数据表
61F-041-R/Q MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-042-K MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-042-K/Q MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-042-R MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-042-R/Q MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-081-K MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-081-K/Q MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-081-R MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-081-R/Q MSYSTEM

获取价格

Field Network Modules 61-UNIT Series
61F-082-K MSYSTEM

获取价格

Field Network Modules 61-UNIT Series