SN54F373, SN74F373
OCTAL TRANSPARENT D-TYPE LATCHES
WITH 3-STATE OUTPUTS
SDFS076A – D2932, MARCH 1987 – REVISED OCTOBER 1993
†
logic symbol
logic diagram (positive logic)
1
1
OE
LE
EN
C1
OE
11
11
LE
3
2
5
1D
2D
3D
4D
5D
6D
7D
8D
1D
1Q
2Q
3Q
4Q
5Q
6Q
7Q
8Q
4
C1
2
1Q
7
6
3
1D
1D
8
9
13
14
17
18
12
15
16
19
To Seven Other Channels
†
This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
‡
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
CC
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –1.2 V to 7 V
I
Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –30 mA to 5 mA
Voltage range applied to any output in the disabled or power-off state . . . . . . . . . . . . . . . . . . . –0.5 V to 5.5 V
Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to V
CC
Current into any output in the low state: SN54F373 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mA
SN74F373 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 mA
Operating free-air temperature range: SN54F373 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
SN74F373 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
recommended operating conditions
SN54F373
SN74F373
UNIT
MIN NOM
MAX
MIN NOM
MAX
V
V
V
Supply voltage
4.5
2
5
5.5
4.5
2
5
5.5
V
V
CC
IH
IL
High-level input voltage
Low-level input voltage
Input clamp current
0.8
–18
– 3
0.8
–18
– 3
24
V
I
I
I
mA
mA
mA
°C
IK
High-level output current
Low-level output current
Operating free-air temperature
OH
OL
20
T
A
–55
125
0
70
2