Power Entry Modules with Line Filter
5707
https://www.schurter.com /PG06
IEC Appliance Inlet C14 or C18 with Filter, Protection Degree IP65 into the Appliance, Fuseholder 1- or
2-pole, Front or Rear Mounting
5707.xxxx.xx2 Mounting from front side
5707.xxxx.xxx.22 with IP 54 V-Lock cord con-
nection
5707 with IP 54 Inlet Gasket
C14
C18
Approvals and Compliances
70° C
70° C
Description
Characteristics
- Panel Mount :
- Extreme robust design
- All single elements are already wired
- Screw type fuse carrier, slotted
- With EMC-shield
Screw-on version from front or rear side , Screws with sealing are in-
cluded
- 4 Functions :
- Especially for applications in rough environments (see technical data)
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Appliance Inlet protection class I or II , Line filter in standard and medi-
cal version , Fuseholder for fuse-links 5 x 20 mm , IP 65 protection into
the appliance
- For front side mounting versions a sealing kit IP 54 for the power sup-
ply connection is available as an accessory: 4700.0021
- Option suffix ".22" offers IP 54 for the power input in combination with
V-Lock cordsets
Other versions on request
- With solder terminals
- Class X1- and Y1-capacitors for enhanced withstand voltage
- Medical version M80
- Additional factory-mounted sealing (IP54) of power input
- Version with current rating 3 A
- Quick connect terminals 6.3 x 0.8 mm
Unique Selling Proposition
- Sealed power entry module
- Strong in Design and Safety
- IP 65 protection to the appliance
- IP 54 protection to the cord connection
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.
The cord latching system prevents against accidental removal of the cordset.
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
1 - 8A @ Ta 40 °C / 250VAC; 50Hz
1 - 8A @ Ta 40 °C / 125VAC; 60Hz
standard < 0.5mA (250V / 60Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7kVDC between L-N
appliance inlet/-outlet
Fuseholder
C14 / C18 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 8A,
Protection Class I or II
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
Dielectric Strength
> 2.7kVDC between L/N-PE
Test voltage (2sec)
for fuse-links 5 x 20mm
Rated Power Acceptance @
Ta 23 °C
5 x 20: 1.6W 1-pole/ 1,2W 2-pole per
pole
Allowable Operation Tempe-
rature
-25°C to 85°C
Power Acceptance @ Ta >
23°C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
Climatic Category
IP-Protection
25/085/21 acc. to IEC 60068-1
from front side IP 65 acc. to IEC 60529
from rear-side IP 65 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw, max 3mm
Line Filter
MTBF
Protection Class
Terminal
Panel Thickness S
> 2'800'000h acc. to MIL-HB-217 F
Mounting screw torque max 0.8Nm
2 screws M3 with sealing are provided
black / white / metallic, UL 94V-0
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
1
EMC Products