ISSUE 2
Installation Instructions for the
4AV Series Vane Sensors
PK 87605
GENERAL INFORMATION
4AV Hall effect vane sensors include a Hall effect
sensor and a magnet in a common package. They
are operated by passing a ferrous vane through the
gap between the magnet and the sensor.
With no vane in the gap, the output is Operated
(conducting). With the vane in the gap, the output is
Released (non-conducting). The vane actuator is
annealed low carbon cold rolled steel, type AISI
1018 or lower in carbon. Minimum recommended
vane dimensions are required to ensure operating
characteristics will be met.
PERSONAL INJURY
DO NOT USE these products as safety or
emergency stop devices or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.
ELECTRICAL CHARACTERISTICS
Supply
Supply
Current
Output
Voltage
Output
Catalog
Listing
Lead
Termination
Voltage
Sink Current
All listings
Length
All Listings
All Listings
All listings
4AV15F
4AV16F
24 AWG Wire
24 AWG Wire
24 AWG Wire
24 AWG Wire
24 AWG Wire
.015 X .025 PCB
5.50 ± 0.25
7.45 ± 0.25
13.15 ± 0.50
18.15 ± 0.50
22.00 ± 0.50
0.140
18.5 mA Max
@ -40 °C
0.4 V Max
@125 °C
0.1 typical
4.5 VDC
through
40 mA Max
15.25 mA typical
4AV17F
26.5 VDC
Dual output
sink currents
are summed
to reach total.
4AV18F
11.75 mA
@25 °C
typical
0.075 V
4AV19F
@25 °C typical
4AV20F
4AV20F-T1*
.025 X .025
Connector
AMP Terminal
Block 103323-4
4AV20F-T2**
.025 X .025
Connector
Molex Terminal
Block 22-05-3041
*Will mate with AMP Connector Housing 87499-8, not supplied
**Will mate with Molex Connector Housing 2695/6471, not supplied
VANE DIMENSIONS (mm/in)
Thickness Min.
Window
Min.
Tooth
Min. Tooth
Depth
1,0/0.4
1,6/.06
10,2/.40
10,2/.40
10,2/.40
6,3/.25
9,27/.365
9,27/.365
Sensing and Control