MODEL: 47LLC
Digital Panel Meters 47 Series
[3] ALARM OUTPUT
0: None
1: N.O. relay contact, 4 points
2: SPDT relay contact, 2 points
3: Photo MOSFET relay, N.O., 4 points
STRAIN GAUGE INPUT DIGITAL PANEL METER
(4½ digit, LED display type)
Functions & Features
• 4½ digit strain gauge input digital panel meter
• 1/8 DIN size
[4] DISPLAY COLOR
R: Red
• Moving average function to suppress the display flickering
• Scaling, tare adjustment, low-end cutout
• Max. and Min. value display
YR: Orange
G: Green
• Safety terminal cover tethered to the device with a strap
• IP66 front panel
BG: Bluegreen
B: Blue
• Separable terminal block
W: White
[5] POWER INPUT
96 (3.78)
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
H
H
DC Power
H
48
(1.89)
P
L
L
L
Zr
o
Sp
n
D/P
R: 24 V DC
Tc
h
Fnc
Mi
n
Max
Ma
x/M
in
A
la
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
rm
/
S
ca
le
/
S
hif
t
U
p
98.5 (3.88)
mm (inch)
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
[6] OPTIONS
MODEL: 47LLC-[1][2][3][4]-[5][6]
blank: none
/Q: With options (specify the specification)
ORDERING INFORMATION
• Code number: 47LLC-[1][2][3][4]-[5][6]
Specify a code from below for each of [1] through [6].
(e.g. 47LLC-S101G-M2/Q)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
/C02: Polyurethane coating
/C03: Rubber coating
[1] INPUT STRAIN GAUGE
S1: 0.0 – 1.0 mV/V
TERMINAL SCREW MATERIAL
/S01: Stainless steel
S2: 0.0 – 3.0 mV/V
EX-FACTORY SETTING
S3: 0.0 – 10.0 mV/V
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9505)
S4: 0.0 – 30.0 mV/V
[2] DC OUTPUT
0: Without
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Current
Degree of protection: IP66; applicable to the front of the
panel meter mounted according to the specified panel
cutout
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
Voltage
Connection: M3 separable screw terminal (torque 0.6 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless
steel
4: 0 – 10 V DC (Load resistance 10 kΩ min.)
5: 0 – 5 V DC (Load resistance 5000 Ω min.)
6: 1 – 5 V DC (Load resistance 5000 Ω min.)
4W: -10 – +10 V DC (Load resistance 10 kΩ min.)
Housing material: Flame-resistant resin (gray)
Isolation: Strain gauge input or excitation or contact input or
SG to DC output to HH output or H output to L output or LL
47LLC SPECIFICATIONS
ES-9505 Rev.8 Page 1/7
http://www.m-system.co.jp/