MODEL: 47DV
Digital Panel Meters 47 Series
[4] I/O OPTIONS
0: None
1: Alarm output: N.O. relay, 4 points
2: Alarm output: SPDT relay, 2 points
3: Alarm output: N.O. photo MOSFET relay, 4 points
(CE not available)
DC INPUT DIGITAL PANEL METER
(5½ digit, LCD display type)
Functions & Features
• 5 1/2 digit DC input digital panel meter
• Scaling range -20000 to 100000
• 1/8 DIN size
4: Network interface: RS-485 / Modbus RTU
5: BCD output
6: Event trigger input
• Display color can be changed at alarm
• Bargraph indicator shows approximate measuring status
• 12 V or 24 V excitation supply
• External event trigger input
• RS-485 / Modbus RTU output
• Infrared interface
7: Alarm output: N.O. relay, 4 points
+ Network interface: RS-485 / Modbus RTU
8: Alarm output: SPDT relay, 2 points +
Network interface: RS-485 / Modbus RTU
9: Alarm output: N.O. photo MOSFET relay, 4 points + BCD output
(CE not available)
• BCD output
A: Event trigger input + BCD output
• Loop test output (DC output option)
• IP66 front panel
• Separable terminal block
[5] POWER INPUT
• Safety terminal cover tethered to the device with a strap
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 50/60 Hz)
DC Power
96 (3.78)
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
P: 110 V DC
M
a
x
M
in
48
(1.89)
F
Z
T
Z
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
H
ld
TG
N
G
Zr
o
Sp
n
Tc
h
Ma
x/M
in
A
la
rm
/
S
ca
le
/
S
hif
t
U
p
98.5 (3.88)
[6] OPTIONS
blank: none
mm (inch)
/Q: With options (specify the specification)
MODEL: 47DV-[1][2][3][4]-[5][6]
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
ORDERING INFORMATION
• Code number: 47DV-[1][2][3][4]-[5][6]
Specify a code from below for each of [1] through [6].
(e.g. 47DV-1111-M2/Q)
/C02: Polyurethane coating
/C03: Rubber coating
• Specify the specification for option code /Q
(e.g. /C01/S01/SET)
TERMINAL SCREW MATERIAL
/S01: Stainless steel
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9501)
[1] INPUT
1: DC voltage
2: DC current
RELATED PRODUCTS
• Resistor module (model: REM2-250)
• Connector terminal block (model: CNT)
• Special cable (model: HDR40)
[2] DC OUTPUT
0: Without
1: With
• Infrared Communication Adaptor (model: COP-IRU)
• PC configurator software (model: 47DCFG)
Downloadable at M-System’s web site.
[3] EXCITATION SUPPLY
1: +12 V sensor excitation
2: +24 V two-wire transmitter excitation
47DV SPECIFICATIONS
ES-9501 Rev.17 Page 1/13
https://www.m-system.co.jp/