High capacitance – small size – Low ESR
FEATURES
UPS – DC link – AC/DC motor controls – Solar heaters - Power
inverters
APPLICATIONS
-40°C to +100°C
Above +85°C applied voltage must be de-rated by 1.5%/°C
Operating Temperature Range
Capacitance Tolerance
+10% at 1 kHz, 25°C
+5% optional
85°C
70°C
85°C
70°C
85°C
575
630
660
720
750
815
700
770
805
885
910
1000
800
880
900
1000
1100
1150
1265
1300
1430
1100
1200
1265
1380
1430
1560
1275
1400
1465
1610
1655
1820
VDC
1000
1035
1150
1170
1300
920
Repetitive
SVDC
Surge
Voltage
1010
1040
1140
Non-
repetitive
SVDC
70°C
Repetitive SVDC: Maximum repetitive voltage for 1 hour Max/Day
VDC
575
240
250
700
285
300
800
315
330
900
350
370
1000
400
1100
420
1275
440
AC voltage
85°C
70°C
VAC
420
440
460
Dissipation Factor (MAX)
Tan δ
C< 4uF
4uF<C<12uF
12uF<C<20uF 20uF<C<40uF 40uF<C<75uF C>75uF
.06
.08
.11
.14
.17
.2
at 1 kHz and 25°C
Lead spacing
Frequency range
10kHz - 60kHz
10kHz – 45 kHz
10kHz – 30 kHz
27.5
37.5
52.5
ESR
RMS current
No RMS current is to be applied at temperatures > +95°C
See standard part listing, No ripple current is to be applied when the ambient temperature
is>+95°C
Ripple current
3000 MΩxuF (10000 MΩxuF typical)
“Not to exceed 3GΩ”
Insulation Resistance
After 1 minute of 100VDC applied between the terminals at 25°C
Self Inductance
<1 nano-Henry per mm of lead spacing and lead length
Capacitance variation <1% MAX after 2 years
Long term stability
Terminal to Terminal
150% of VDC or 150% of VAC applied 3KVAC at 50/60 Hz applied between the terminals
for 10 Seconds and 25°C and case for 60 Seconds and 25°C
Terminal to case
Dielectric Strength