3 Phase RHP - Hybrid Solid State Contactors
3 Phase Contactor
3 Phase Contactor
DC Input
40-50 Amp
120/240 VAC
AC Input
40-50 Amp
280/600 VAC
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
DC logic compatible input
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
CE compliant & UL/cUL recognized
1
CONTROL SPECIFICATIONS
Control Voltage Suffix
Coil Voltage Range
Min. Turn-On Voltage
Min. Turn-Off Voltage
Coil Power Consumption, Inrush
Coil Power Consumption, Sealed
Coil Terminals
1
CONTROL SPECIFICATIONS
Control Voltage Suffix
Control Voltage Range
Max. Reverse Voltage
Min. Turn-On Voltage
E
F
G
D5
D12
D24
20 - 26 VAC, 50/60 Hz 100 - 130 VAC, 50/60 Hz 208 - 240 VAC, 50/60 Hz
4.5 - 5.5 VDC
-5.5 VDC
4.5 VDC
10 - 15 VDC
-15.5 VDC
9.5 VDC
22 - 27 VDC
-27.5 VDC
9.5 VDC
20 VAC
12 VAC
100 VAC
208 VAC
24 VAC
48 VAC
56 VA @ 24 VAC
6.6 VA @ 24 VAC
10 in lb (1.13 Nm)
56 VA @ 120 VAC
6.6 VA @ 120 VAC
10 in lb (1.13 Nm)
56 VA @ 220 VAC
6.6 VA @ 220 VAC
10 in lb (1.13 Nm)
Min. Turn-Off Voltage
Input Current
1 VDC
12mA @ 5 VDC
5.31 in lb (0.6 Nm)
2 VDC
12mA @ 12 VDC
5.31 in lb (0.6 Nm)
2 VDC
12mA @ 24 VDC
5.31 in lb (0.6 Nm)
Input Connector
1
1
OUTPUT SPECIFICATIONS
OUTPUT SPECIFICATIONS
28
60
Voltage suffix
Operating Voltage (50/60Hz)
Voltage suffix
Operating Voltage (50/60Hz)
12
24
24 - 280 VAC
48 - 600 VAC
100 - 120 VAC
208 - 240 VAC
0.06 mA @ 240 VAC
3
3
Maximum Off-State Leakage Current per channel
0.05 mA @ 240 VAC
0.06 mA @ 480 VAC
Maximum Off-State Leakage Current per channel
0.05 mA @ 120 VAC
40
50
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
40
50
2
40 A Resistive
50 A Resistive
Dual quick connect and Box
2
40 A Resistive
50 A Resistive
Dual quick connect and Binder
Dual quick connect and Binder Dual quick connect and Box
head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6
head screws / AWG#14 - AWG#8 lugs / AWG#14 - AWG#6
Screw torque requirements
18 in lbs (2.1 Nm)
25 in lbs (2.9 Nm)
Screw torque requirements
18 in lbs (2.1 Nm)
25 in lbs (2.9 Nm)
1
1
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation.
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation
4000 VAC
2500 VAC
4000 VAC
Input/Output to Ground Dielectric Isolation.
Input/Output to Ground Dielectric Isolation
2500 VAC
Three Normally Open
-20°C to 75°C
3
3
Contacts (Double Break )
Three Normally Open
Contacts (Double Break)
4
4
Ambient Operating Temperature Range
-20°C to 75°C
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
Max. Turn-Off Time
Maximum Number of Operations per Minute
Maximum Number of Operations per Minute
> 2 Million operations
Lifetime @ Rated Load Current, 40°C ambient
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
> 2 Million operations
temp, 30 operations/min, Rated Vcontrol
540 grs (1.19 lb)
Weight (typical)
540 grs (1.19 lb)
Weight (typical)
1
Specificationts @ 25°C unless otherwise noted.
1
2
3
4
Specificationts @ 25°C unless otherwise noted.
2
See Derating Curves for additional operational conditions.
See Derating Curves for additional operational conditions.
3
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
4
Part Number Nomenclature
Derating Curves
Load Current
40: 40 Amps
50: 50 Amps
3RHPXX50XX
3RHPXX40XX
55
50
45
40
35
30
25
20
SERIES
45
40
35
30
25
20
3 RHP 12 40 D5
Three
Phase
Device
Operating
Voltage VAC
50/60 Hz
Nominal Coil
Power lead size
AWG # 6
/Control Voltage
Power lead size
AWG # 6
AWG # 8
D5: 5 VDC
D12: 12 VDC
D24: 24 VDC
12: 120 V 1-phase
AWG # 8
24: 240 V 3-phase
or 1-phase
Safe Operating Area
Safe Operating Area
E: 24 VAC
F: 120 VAC
G: 220 VAC
28: 280 V 3-phase
60: 600 V 3-phase
25
35
45
55
65
75
25
35
45
55
65
75
Ambient Temperature, °C
Ambient Temperature, °C