3G3MV Inverters
3InvGerter3s MV
A032
Versatile Compact Inverter Offers Loop
Vector and V/Hz Control
• Intuitive digital operator controls all parameter selections
and settings
• Quick Start LEDs for fast setup and troubleshooting
• Standard PID control
• Modbus serial communications standard
• DeviceNet communications unit (optional) allows remote
monitoring of Run/Stop status and operating conditions, and
making changes to set values
• Fine-tune speed using the potentiometer on the digital
operator
• User-selectable open loop vector and V/Hz control methods
• NEMA 4X models meet requirements for tough washdown
and dust-tight environments
• NEMA 1 models available
• Compact size: Single phase, 230 VAC: 148 H x 170 W x
180 D mm max.
• Three-phase, 230 VAC: 260 H x 180 W x 170 D mm max.
• Three-phase, 460 VAC: 260 H x 180 W x 170 D mm max.
• Integrate a full-featured PLC into 3G3MV inverters with
6 input/4 output points, encoder input, interrupt inputs and
pulse outputs; dual port RAM for 200 transfers per second;
eliminates point-to-point wiring
Specifications
General Specifications
Power supply
Rated input voltage & frequency 3-phase, 200 to 230 V, 50/60 Hz
Single-phase, 200 to 240 V, 50/60 Hz
3-phase, 380 to 460 V, 50/60 Hz
Allowable voltage fluctuation
Allowable frequency fluctuation
Control characteristics
Control method
-15% to +10%
5%
Sine wave PWM (V/f control or voltage vector control, selectable);
possible to program any V/f pattern
Frequency control range
0.1 to 400 Hz
Frequency accuracy
(temperature change)
Digital reference: 0.01%, 14 to 122°F (-10 to +50°C)
Analog reference: 0.5%, 59 to 95°F (25 10°C)
Frequency setting resolution
Digital reference: 0.1 Hz (less than 100 Hz)/0.1 Hz (100 Hz or more)
Analog reference: (0:06/60 Hz) equivalent to 1/1000 of max. output frequency
Output frequency resolution
Overload capacity
0.01 Hz
150% rated output current for one minute
Frequency setting signal
0 to 10 VDC (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) pulse train input, frequency setting potentiometer
(Selectable)
Accel/Decel
0.01 to 6000 seconds (accel/decel time are independently programmed 2 types)
Braking torque
Short-term average deceleration torque:
0.1, 0.25 kW (0.13 HP, 0.25 HP): 150%; 0.55, 1.1 kW): (0.5 HP, 1 HP): 100% 1.5 kW (2 HP): 50%; 2.2 kW (3 HP)
or more: 20%
Continuous regenerative torque: Approx. 20% (150% with optional braking resistor, braking transistor built-in)
I-18