360ACMOP_S4 Series
360W - Open Frame Type Switching Power Supply - Universal Input - Isolated & Regulated
AC-DC Converter
360 Watt
Universal input: 90~264VAC
High efficiency: >91% typical
Short circuit protection (SCP)
Over power protection (OPP)
Over voltage protection (OVP)
High Power density, 360W in
6“ x 4“ footprint
ITE & Medical approvals
Medical applications
The 360ACMOP_S4 series is a compact size power converter offered by
Gaptec. It features universal input voltage, taking AC input voltage, low
power consumption, high efficiency, high reliability, safer isolation. It
offers good EMC performance, meets IEC/EN61000-4, CISPR22/EN55022,
protection: Means of patient
protection (MOPP)
Altitude at operation: ITE up to UL60950 and EN60950 standards, and is widely used in medical instru-
5000m, Medical below 3000m
mentation and critical applications in commercial and industrial elec-
Main output and Standby out- tronic equipment.
Meet Medical BF rated
put Power ON LED indicators
Approval
Model
Power
[W]
Output voltage
[V]
Load [A, max]
Ripple&Noise Standby supply Fan output
Efficiency
[230VAC, %, typ]
convection 18CFM Forced Air
[mV, V1]
[V/A, V2]
[V/A, V3]
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
360ACMOP_12S4
360ACMOP_24S4
360ACMOP_28S4
360ACMOP_48S4
360ACMOP_56S4
360
360
360
360
360
12
24
28
48
56
20.84
10.42
8.93
5.21
30
15
120
5/0.5
12/0.3
>90
>90
>90
>90
>90
240
5/0.5
12/0.3
12.86
7.5
280
5/0.5
12/0.3
300
5/0.5
12/0.3
4.63
6.67
300
5/0.5
12/0.3
Input specifications
Input voltage range
Input frequency
Power factor
Output specifications
90-264 VAC
Item
Test conditions
Min Typ
Max
250
Units
W
47~63Hz
Convection total
power
115VAC
• 0.95(max)
230VAC
• 0.90 (max)
18CFM Forced air
total power
360
W
Input current
115VAC
• 5A (max)
230VAC
• 2.5A (max)
Output voltage
accuracy
Full load
2
%
Inrush current
(cold start @25°C)
115VAC
• 40A (typ)
230VAC
• 80A (typ)
Hold-up time
@full load, 115VAC
10
ms
Leakage current
< 100µA/264VAC
Note:
Protection specifications
1. This product is not designed for use in critical life support systems, equipment
used in hazardous environment, nuclear control systems or other such
applications which necessitate specific safety and regulatory standards other
the ones listed in this datasheet.
Short circuit
protection
Protection type:
Auto-recovery
Over-voltage
protection
Protection type:
Latching type, AC recycle
2. Output connector options:
Z=T ( Terminal block type, pitch 8.25mm): Suitable for all voltages
Z=C ( Connector type, pitch=3.96mm ): Suitable for 24V up
3. All models are equiped with 5Vsb & 12V fan outputs.
4. All models have total power 250W Max. convection or 360W Max. forced air
cooling.
5. Ripple and noise are measured at oscilloscope 20MHz bandwidth by a 10uF elect-
rolytic capacitor and a 0.1uF ceramic capacitor in parallel at output connector.
Over-power
protection
Protection type:
105% to 150% maximum rating, auto-recovery
Example:
360ACMOP_12S4
360= 360Watt; AC= AC-DC; MOP= series; 12Vout; S= Single Output;
4= 4kVAC
Page 1 of 4
360ACMOP_S4 – Rev. 2019-1.0
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG