3M™ Round, Shielded/Jacketed, Disc. Wire Cable
28AWG Stranded, Twisted Pair, PVC/PVC
3600X Series
•ꢀ Meets external wiring requirements of National
Electrical Code, Article 725 (CL2)
•ꢀ 28AWG stranded wire provides flexibility
•ꢀ Twisted pairs reduce crosstalk for balanced drive
applications
•ꢀ Dual shielding with aluminum film foil and copper
braid provides excellent EMI/ESD protection
•ꢀ Wires are color coded for easy identification
•ꢀ 35 db average shielding effectiveness
•ꢀ See Regulatory InformationAppendix (RIA) for
chemical compliance information
(RIA E1 & C1 apply)
Date Modified: May 11, 2009
TS-0388-B
Sheet 1 of 2
Physical
Jacket Material: Polyvinyl Chloride (PVC); Color: Beige
Primary Material: PVC
Marking:
Standard: (UL) CL2 75C 28AWG
3M XX
C
AWM IIA/B 80C 150V FT1 EU <50V
(where XX may be NU, MR or NW)
Conductors: 28AWG, 7 × 36AWG [ 7 × Ø 0.127 ] Tinned Stranded Copper
0.001 [ 0.03 ] ThickAluminum/Polyester Film Foil and
90% Coverage Tinned Copper Braid
Shielding:
Electrical
USA: N.E.C. 725, CL2
Canada: 150V
EU: <50V
Voltage Rating:
(Primary Cable) > 1 × 1010 Ω/10 ft. [ 3 m ]
Insulation Resistance:
Unbalanced
58 Ω
Balanced
91 Ω
Characteristic Impedance:
29.2 pF/ft [ 95.8 pF/m ]
18.5 pF/ft [ 60.7 pF/m ]
Capacitance:
Inductance:
0.10 μH/ft [ 0.33 μH/m ] 0.15 μH/ft [ 0.49 μH/m ]
1.69 ns/ft [ 5.54 ns/m ]
60%
1.69 ns/ft [ 5.54 ns/m ]
60%
Propagation Delay:
Velocity of Propagation:
Note: Unbalanced is measured between conductors within a pair with one conductor connected to the shield. Balanced is measured between conductors within a pair with the shield floating.
Environmental
Temperature Rating: USA: CL2; 75°C Max
Canada: +80°C
Canada: FT1
Flammability Rating: USA: N.E.C. 725, CL2
UL File No.: E118773, Power Limited Circuit Cable; CL2
3M is a trademark of 3M Company.
For technical, sales or ordering information call
3
Interconnect Solutions
http://www.3M.com/interconnects/
800-225-5373