Multiple Case Sizes - High Voltage – High Current
Bulk Filtering – Switching Power Supplies
FEATURES
APPLICATIONS
-40°C to +105°C (<100WVDC)
-25°C to +105°C (>160WVDC)
Operating Temperature Range
Capacitance Tolerance
+20% at 120 Hz, 20°C
WVDC
Surge Voltage
10
13
10
.6
16
20
16
.45
25
32
25
.3
35
44
35
.25
50
63
50
.2
63
79
63
.15
80
100 160 200 250 350
400 450
450 500
400 450
SVDC
100 120 200 250 300 400
80
.15
WVDC
100 160 200 250 350
.15 .15 .15 .15 .15
Dissipation
Factor
.2
.2
tan δ
(120 Hz)
For capacitances above 33000uF, add to DF value (Capacitance-33000) *0.1
10000
Time
5 Minutes
Leakage Current
@20°C, Rated WVDC applied
3√CV
WVDC
10
6
15
16
6
15
25
6
15
35
6
15
50
4
15
63
3
15
80 100 160 200 250 350 400 450
Impedance Ratio
-25°C/+20°C
3
15
3
8
-
8
-
8
-
8
-
8
-
8
-
(120 Hz)
-40°C/+20°C
5000 hours at 105°C with rated WVDC and ripple current applied
Capacitance change
Dissipation factor
Leakage current
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
1000 hours at 105°C with no voltage applied
<20% of initial measured value
Load Life
Capacitance Change
Dissipation Factor
Leakage Current
Shelf Life
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Temperature (°C)
WVDC
<100
160<V<250
>350
60
0.9
0.8
0.8
120
1.0
1.0
1.0
400
1.0
1.0
1.0
1k
10k
1.25
1.47
1.47
50k
1.25
1.47
1.47
45
2.4
2.4
2.4
65
2.1
2.1
2.1
75
1.9
1.9
1.9
85
1.7
1.7
1.7
105
Ripple Current
Multipliers
1.15
1.25
1.3
1
1
1