Thermal Overcurrent Circuit Breaker 3130
Description
Single, two and three pole rocker switch/thermal trip free circuit breakers
(S-type TO CBE to EN 60934) of compact design for snap-in panel
mounting. Available either with protection on one/both/all poles or,
in the case of the double pole version, protection on one pole only.
Illumination is optional and there is a choice of rocker colours.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Motors, transformers, solenoids, household and office machines, electrical
tools, mobile homes, boating, construction vehicles, medical equipment
to EN 60601.
1
3130
1-pole
3-pole
Standard current ratings and typical internal resistance values
Technical data
Current
Internal resistance Current
Internal resistance
rating (A) per pole (Ω)
rating (A) per pole (Ω)
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Typical life
AC 240 V; 3 AC 415 V; DC 50 V
(UL: AC 250 V; 3 AC 250 V; DC 50 V)
0.1
0.2
0.3
0.4
0.5
0.8
1
94
4
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
24
5
0.1...20 A 1-pole
0.1...16 A 2- and 3-pole
12
6
1-pole
5.30
4.20
1.50
0.9
7
AC 240 V: 0.1...20 A 30,000 operations at 1 x IN, inductive
DC 50 V:
0.1...4 A
30,000 operations at 1 x IN, inductive
8
4.5...16 A 30,000 operations at 1 x IN, resistive
0.1...20 A 30,000 operations at 1 x IN, inductive
2-pole
10
12
14
15
16
18
20
DC 28 V:
AC 240 V: 0.1...16 A 50,000 operations at 1 x IN, inductive
DC 50 V:
0.1...16 A 50,000 operations at 1 x IN, inductive
1.2
1.5
2
0.80
0.45
0.27
0.0785
0.0595
0.0565
3-pole
3 AC 415 V: 0.1...16 A 30,000 operations at 1 x IN, inductive
Ambient temperature
-30...+60 °C (-22...+140 °F)
rated impulse pollution
Insulation co-ordination
(IEC 60664 and 60664 A) withstand voltage
2.5 kV
2.5
3
degree
2
reinforced insulation in operating area
3.5
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area AC 3,000 V
current path/current path AC 1,500 V
Illumination voltage/power consumption
Insulation resistance
> 100 MΩ (DC 500 V)
operating voltage
power consumption
Interrupting capacity Icn
0.1...2 A
10 x IN
150 A
250 A
150 A
130 A
1-pole
2-/3-pole
Y+R
2-/3-pole
G
2.5...20 A
2.5...16 A
2.5...12 A
14 + 16 A
1-pole
2-pole
3-pole
3-pole
12 V
9 mA
9 mA
9 mA
< 1 mA
< 1 mA
-
2 mA
3.5 mA
3.5 mA
3.5 mA
2.8 mA
2.8 mA
2.8 mA
Interrupting capacity (UL 1077)
IN
24 V
2 mA
UN
Inc
48 V
2 mA
1, 2-pole
3-pole
0.1...16 A
0.1...12 A
0.1...16 A
AC 250 V
3 AC 250 V
DC 50 V
3500 A
115 V
230 V
400 V
0.9 mA
0.9 mA
0.9 mA
5000 A
2000 A
1,2-pole
Degree of protection
(IEC 60529/DIN 40050)
operating area IP40
terminal area IP00
Vibration
5 g (57-500 Hz) 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion
Humidity
Mass
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 45 g (three pole)
approx. 31 g (double pole)
approx. 17 g (single pole)
1646
www.e-t-a.de
1