5秒后页面跳转
30LVT22-R PDF预览

30LVT22-R

更新时间: 2024-11-09 13:04:31
品牌 Logo 应用领域
威世 - VISHAY 电容器
页数 文件大小 规格书
3页 132K
描述
CAPACITOR, CERAMIC, X7R, 0.00022 uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT

30LVT22-R 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:Active包装说明:, 3320
Reach Compliance Code:compliantECCN代码:EAR99
HTS代码:8532.23.00.60风险等级:5.64
其他特性:RATED AC VOLTAGE (V): 400电容:0.00022 µF
电容器类型:CERAMIC CAPACITOR介电材料:CERAMIC
高度:11.6 mmJESD-609代码:e3
长度:8.4 mm安装特点:THROUGH HOLE MOUNT
多层:No负容差:10%
端子数量:2最高工作温度:125 °C
最低工作温度:-30 °C封装形状:DISK PACKAGE
封装形式:Radial包装方法:Bulk
正容差:10%额定(AC)电压(URac):300 V
尺寸代码:3320表面贴装:NO
温度特性代码:X7R温度系数:15% ppm/ °C
端子面层:Matte Tin (Sn) - with Nickel (Ni) barrier端子节距:6.4 mm
端子形状:WIRE宽度:5 mm
Base Number Matches:1

30LVT22-R 数据手册

 浏览型号30LVT22-R的Datasheet PDF文件第2页浏览型号30LVT22-R的Datasheet PDF文件第3页 
440L, 30LV, 30LVS, 25Y, 125L, 20VL Series  
Vishay Cera-Mite  
AC Line Rated Disc Capacitors  
X & Y EMI/RFI FILTER TYPES: ACROSS-THE-LINE,  
LINE-BY-PASS, ANTENNA COUPLING  
Vishay Cera-Mite AC Line Rated Discs are rugged, high voltage capacitors specically designed and tested  
for use on 125 Volt through 600 Volt AC power sources. Certied to meet demanding X & Y type worldwide  
safety agency requirements, they are applied in across-the-line, line-to-ground, and line-by-pass  
ltering applications. Vishay Cera-Mite offers the most  
complete selection in the industrysix product families—  
exactly tailored to your needs.  
AC LINE RATED CERAMIC CAPACITOR SPECIFICATIONS  
PERFORMANCE DATA / SERIES: 440L 30LV 30LVS 25Y 125L 20VL  
Worldwide Safety Agency Recognition  
- Underwriters Laboratories - UL1414 & UL1283  
Application Voltage Range  
(Vrms 50/60 Hz) (Note 1)  
Dielectric Strength  
250/500 300/400 250/400 250/400 250  
250  
- Canadian Standards Association - CSA 22.2 No. 1 & No. 8  
- European EN132400 to IEC 384-14 Second Edition  
Required In AC Power Supply and Filter Applications  
Six Families Tailored To Specific Industry Requirements  
Complete Range of Capacitance Values  
4000 2500 2500 2500 2000 1250  
(Vrms 50/60 HZ for 1 minute)  
Dissipation Factor (Maximum)  
Insulation Resistance (Minimum)  
Mechanical Data  
2%  
1000 F  
Service Temperature 125°C Maximum;  
Coating Material per UL94V0  
Temperature Characteristics  
Y5U  
Y5U Y5U  
Y5S Y5V Y5V  
See Part Number Detail for Temperature Characteristics  
SAFETY AGENCY RECOGNITION AND EMI/RFI FILTERING SUBCLASS  
Series / Recognition / Voltage  
Underwriters Laboratories Inc.: (Note 2)  
UL 1414 Across-The-Line  
440L  
30LV  
30LVS  
25Y  
125L  
20VL  
Across-The-Line Across-The-Line  
Antenna-Coupling Antenna-Coupling  
UL 1414 Antenna Coupling  
Line-By-Pass  
250 VAC  
UL 1414 Line-By-Pass  
UL 1414 Rated Voltage  
Electromagnetic Interference Filters  
UL1283 Rated Voltage  
Line-By-Pass  
250 VAC  
EMI Filters  
600 VAC  
Line-By-Pass  
250 VAC  
EMI Filters  
250 VAC  
Line-By-Pass  
250 VAC  
EMI Filters  
250 VAC  
Line-By-Pass  
250 VAC  
EMI Filters  
250 VAC  
EMI Filters  
250 VAC  
Canadian Standards Association:  
CSA 22.2 No.1 Across-The-Line  
CSA 22.2 No.1 Isolation  
CSA 22.2 No. 1 Rated Voltage  
CSA 22.2 No. 8 Line-to-Ground Capacitors  
For Use in Certified EMI Filters  
CSA 22.2 No. 8 Rated Voltage  
Across-The-Line Across-The-Line  
Isolation  
250 VAC  
Isolation  
250 VAC  
Isolation  
125/250 VAC  
Isolation  
250 VAC  
Isolation  
250 VAC  
Line-To-Ground  
Certified EMI Filters Certified EMI Filters Certified EMI Filters  
400 VAC 400 VAC 400 VAC  
Line-To-Ground  
Line-To-Ground  
Line-To-Ground  
Certified EMI Filters  
250 VAC  
European CENELEC Electronic Components Committee (CECC) EN 132 400 to Publication IEC 384-14 Table II, Edition 2:  
IEC 384-14 Second Edition Subclass Y: (Note 3)  
Subclass Y Voltage (Vrms 50-60 Hz)  
Type of Insulation Bridged  
Y1  
500 VAC  
Double or  
Reinforced  
8 kV  
Y2  
300 VAC  
Basic or  
Supplementary  
5 kV  
Y2  
250 VAC  
Basic or  
Supplementary  
5 kV  
Y2  
250 VAC  
Basic or  
Y4  
125 VAC  
Basic or  
Supplementary Supplementary  
Peak Impulse Voltage Before Endurance Test  
IEC 384-14 Second Edition Subclass X: (Note 4)  
Subclass X Voltage (Vrms 50-60 Hz)  
Peak Impulse Voltage in Service  
5 kV  
X1  
400 VAC  
2.5 to 4.0 kV  
High Pulse  
2.5 kV  
X1  
400 VAC  
2.5 to 4.0 kV  
High Pulse  
X2  
X1  
X1  
X1  
400 VAC  
2.5 to 4.0 kV  
High Pulse  
400 VAC  
2.5 to 4.0 kV  
High Pulse  
400 VAC  
2.5 to 4.0 kV  
High Pulse  
400 VAC  
To 2.5 kV  
Gen. Purpose  
Application  
Damp Heat, Steady State Recognition  
Code HKF - 25°C/ + 125°C/21 days  
Note 1  
Note 3  
Class X capacitors are divided into subclasses  
according to the peak impulse test voltage  
superimposed on the main voltage  
Voltage Ratings: All ratings are manufacturers  
rating.  
IEC 384-14 Subclass Y Capacitors:  
A capacitor of a type suitable for use in situations  
where failure of the capacitor could lead to  
danger of electric shock.  
ClassY capacitors are divided into sub- classes  
based on type of insulation bridged and voltage  
ranges.  
For definitions of basic, supplementary,  
double and reinforced insulation, see IEC  
Publication 536.  
Part markings are governed by agency  
rules and customer requirements.  
Parts are marked 250 VAC unless otherwise  
requested.  
Note 5  
AC Leakage Current:  
For all Series (except 125L) - AC Leakage  
Current (mA) specified at 250 Vrms, 60 Hz.  
Note 2  
• For 125L Series  
- AC Leakage Current  
UL1414 Across-The-Line, Antenna Coupling, and  
Line-By-Pass Capacitors:  
(mA) specified at 125 Vrms, 60Hz.  
Subclass  
Y capacitors may be used in  
Across-The-LineA capacitor connected  
either across a supply circuit or between  
one side of a supply circuit and a conductive  
part that may be connected to earth ground.  
Antenna-CouplingA capacitor connected  
from an antenna terminal to circuits within an  
appliance.  
Line-By-PassA capacitor connected between  
one side of a supply circuit and an accessible  
conductive part.  
Note 6  
applications which require  
X rating.  
a Subclass  
Alternate Lead Spacings of 7.5mm and 10mm  
are available bulk or tape & reel.  
European Required Minimum Lead Clearance  
(Prevents Use of Inside Crimp) .315" (8mm) on  
440L Series; 0.118" (3mm) on all other series.  
Note 4  
IEC 384-14 Subclass X Capacitors:  
A capacitor of a type suitable for use  
in situations where failure of the capacitor  
would not lead to danger of electric  
shock.  
www.vishay.com  
20  
Document Number: 23092  
Revision 14-May-02  
ceramite.support@vishay.com  

与30LVT22-R相关器件

型号 品牌 获取价格 描述 数据表
30LVT33 VISHAY

获取价格

AC Line Rated Disc Capacitors
30LVT33BK-R VISHAY

获取价格

CAP,CERAMIC,330PF,10% -TOL,10% +TOL,X7R TC CODE,-15,15% TC
30LVT33-R VISHAY

获取价格

CAPACITOR, CERAMIC, X7R, 0.00033 uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
30LVT47 VISHAY

获取价格

AC Line Rated Disc Capacitors
30LVT47BK-R VISHAY

获取价格

CAP,CERAMIC,470PF,10% -TOL,10% +TOL,X7R TC CODE,-15,15% TC
30LVT47-R VISHAY

获取价格

CAPACITOR, CERAMIC, X7R, 0.00047 uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
30LVT47RK-R VISHAY

获取价格

CAP,CERAMIC,470PF,10% -TOL,10% +TOL,X7R TC CODE,-15,15% TC
30LVT56 VISHAY

获取价格

AC Line Rated Disc Capacitors
30LVT56-R VISHAY

获取价格

CAPACITOR, CERAMIC, X7R, 0.00056 uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
30LVT68 VISHAY

获取价格

AC Line Rated Disc Capacitors