Instruction Sheet
Die Assemblies 45218, 45221,
69303-2, and 69820
408-1634
04 JAN 10 Rev C
Insert Anvil
(Moving Die)
Dimensions on this instruction sheet are in
NOTE
millimeters [with inches in brackets]. Figures are
not drawn to scale.
i
Insert Indenter
(Stationary Die)
Reasons for reissue of this instruction sheet are
provided in Section 8, REVISION SUMMARY.
Screw
2. DESCRIPTION
Ejector
The die assembly consist of an insert indenter
(moving die) and an insert anvil (stationary die).
The stationary die is identified by the chamfered
corners. The stationary die is marked with the die
assembly part number, wire size (AWG), and splice
type. When mated, the die assembly forms one
crimping chamber. Each die is secured in the tool by
a single screw.
Locator (Except Die
Assembly 69820)
DIE ASSEMBLY
PART
SPLICE
MINIMUM OPENING
DIAMETER
MARKING
SIZE
NUMBER
3. DIE INSTALLATION
Install the die assembly onto the tool according to the
instructions supplied with the tool. If using the
pneumatic tooling assembly, follow the instructions
supplied with the applicable crimper or adapter.
18--16
45218
22--14
—
—
ECV--ECN
18--10
ECV--ECN
45221
22--10
22--16
69303--2
69820
18--16 EC
6.73 mm [.265 in.]
6.48 mm [.255 in.]
4. CRIMPING PROCEDURE
18--16 ECVG
22--16
Die Assembly 69820 requires an insulation crimp
adjustment. Before crimping any splices, refer to
Section 5 for proper adjustment.
NOTE
Figure 1
i
1. INTRODUCTION
1. Select proper wire combinations as stated in the
applicable wire combination chart specified in
Figure 2. Strip wires to length indicated in Figure 2.
Do not use wires with nicked or missing strands.
Die Assemblies 45218, 45221, 69303--2 (shown in
Figure 1), and 69820 are used with the following tools
to crimp vinyl closed--end splices and nylon
closed--end splices onto solid and stranded wire sizes
22 through 10 AWG. For specific information
concerning the tools, refer to instruction sheet
(408--series) or customer manual (409--series) listed.
If conductors are twisted together to form a tight
bundle before inserting them into the splice, the
strip length must be maintained after twisting.
NOTE
i
REFERENCE
DOCUMENT
2. Insert the splice, wire barrel first, into the ejector
of the stationary die until splice bottoms. For nylon
splices, the shoulder must rest against the ejector;
for vinyl splices, the end of the wire barrel of must
rest against the locator. Die Assembly 69820 does
not have a locator; therefore, the wire barrel must
rest against the wire barrel section of the die. See
Figure 3. Close dies until splice is held in place.
TOOL
Straight Action Hand Tool 69710--1
408--2095
626 Pneumatic Tooling Assembly
189721--1 or 189722--1
Fitted with Straight Action Crimper
217200--1 or 189721--2
409--5862
408--4195
626 Pneumatic Tooling Assembly
189722--2
Fitted with C--Head Pneumatic Adapter
318161--1
3. Insert stripped wires into splice wire barrel until
conductors bottom. See Figure 3.
409--5862
408--4190
Always keep fingers clear of dies during tool
operation.
DANGER
Read these instructions and referenced documents
before crimping any splices.
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.tycoelectronics.com
E2010 Tyco Electronics Corporation, Harrisburg, PA
All International Rights Reserved