Spezifikation für Freigabe / specification for release
Kunde / customer:
Artikelnummer / part number:
3020302
WE-LT Leitende Textildichtung
WE-LT Conductive shielding gasket
Bezeichnung :
description :
DATUM / DATE : 2006-03-21
A Mechanische Abmessungen / dimensions:
Rechteck-Profil / square profile
B
H
L
3,0
2,0
1000,0
mm
mm
mm
4
H
1
B
B
2
2
H
3
L
1
#BEZUG!
B Elektrische Eigenschaften / electrical properties:
Eigenschaften / properties
Einfügungsdämpfung:maximum /
insertion loss:maximum
≥ 80 dB / 100 MHz (basierend auf / based on MIL-STD-225)
≥ 75 dB / 1 GHz
Oberflächenwiderstand /
Surface resistivity
< 0,08 Ohm
Nicht brennbar - selbstverlöschend / non-inflammable - self-extinguishing
D Testbedingungen / test conditions:
Luftfeuchtigkeit / humidity:
E Eigenschaften / general specifications:
33%
Lagertemperatur / storage temperature:
-25°C - +85°C
Umgebungstemperatur / temperature:
+20°C
Betriebstemperatur / operating temperature:
-25°C - +85°C
F Werkstoffe & Zulassungen / material & approvals:
No.
1
Generic Name
Metallized Fiber
Grade Name
SUI-13-#FR
UL File No.
E178902
Flame Class
UL94VTM-0
Thickness
130 mic.
Max 34,74 mm;
min. 0,74 mm
Polyether Urethane Foam
2
UEM-55(CY)
E188467
94V-0
Rayon Paper with acrylic Adhesive
3
4
750F
E125972
none
UL94VTM-0
none
0,16 mm
Reactive Polyurethane Hotmelt Adhesive
HI-BON No. 4832
50 mic.
Kunde / customer
Freigabe erteilt / general release:
..................................................................................
...............................................................................
Unterschrift / signature
Würth Elektronik
Datum / date
SSt
Version 2
06-03-21
..................................................................................
...............................................................................
SSt
Version 1
05-11-09
Geprüft / checked
Kontrolliert / approved
Name
Änderung / modification
Datum / date
This electronic component is designed and developed with the intention for use in general electronics equipments. Before incorporating the components into any equipments in the field such as aerospace,
aviation, nuclear control, submarine, transportation, (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc. where higher safety and
reliability are especially required or if there is possibility of direct damage or injury to human body. In addition, even electronic component in general electronic equipments, when used in electrical circuits that
require high safety, reliability functions or performance, the sufficient reliability evaluation-check for the safety must be performed before use. It is essential to give consideration when to install a protective
circuit at the design stage.
Würth Elektronik eiSos GmbH & Co. KG
D-74638 Waldenburg · Max-Eyth-Strasse 1 - 3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400
http://www.we-online.com
SEITE 1 VON 1