www.make-ps.com
E-mail:info@make-ps.com
3000LP series
Single, Dual, Triple Output
DC/DC Converter
FEATURES
• 6 sided Continuous Shielding
• Synchronization and Output Trim
• Wide 2:1 Input Voltage Range
• Efficiency to 82%
• UL 1950 Approved
• CSA 22.9-950 Approved
• VDE / EN 60950 Approved
,
• >600 000 Hours MTBF
INPUT CHARACTERISTICS
DESCRIPTIONS
Unit/Comments
Min Typ Max
The 3000LP series is a family of compact 25W to 30W, high
performance DC/DC converters. These converters are
specifically designed to provide the flexibility, power density,
and reliability required to fulfill local power needs in
applications ranging from telecom switch systems to
portable instrumentation. 24 models operate over 2:1 input
ranges of 9 to 18, 18 to 36 or 36 to 72 VDC; providing single,
dual or triple output combinations of 5, 12, 15, 5, 12, 15,
5 12 and 5 15 VDC. All models are packaged in compact,
low profile 3.0” X 2.56” X 0.4” metal cases.
Input Voltage Range
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Over Voltage Shutdown
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Remote ON / OFF Control
Supply ON
VDC
VDC
VDC
9
12 18
18 24 36
36 48 72
VDC
VDC
VDC
20
40
74
5.5 VDC or Open Circuit
0 VDCto 0.8VDC
Supply OFF
OUTPUT CHARACTERISTICS
Logic Referenced to Negative Input
Reverse Polarity Input Current
Input Filter
Amp
Pi Filter
See Model Selection
Guide
12
Min Typ Max Unit/Comments
Output Voltage Accuracy
Input Fuse Rating
1
Single & Dual Outputs
Triple Outputs- Primary
1.0 %
1.0 %
5.0 %
1
1
1
- Auxiliaries
Output Voltage Adjustment
Voltage Balance:
Dual Outputs
5.0 % ; G Case Only
2.0 %; Equal Output Loads
100 mV; Equal Output Loads
10% Full Load
Triple Outputs (Auxiliaries)
Minimum Load
GENERAL CHARACTERISTICS
Line Regulation
Single Outputs
2
0.5 %
Min Typ Max Unit/Comments
2
Dual Outputs
1.0 %
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
100
1000
1000
kHz
2
Triple Outputs- Primary
- Auxiliaries
0.2 %
5.0 %
VDC, 1 minute
Mohm, 500VDC
pF, 100kHz, 1Volt
2
Load Regulation
Single Outputs
190
3
0.5 %
3
Dual Outputs
1.0 % ; Equal Loads
Single and Dual Outputs 685
Thousand Hours,
3
o
Triple Outputs- Primary
- Auxiliaries
Ripple/Noise
5V Outputs
1.0 %
+25 C, Ground
3
2.0 % ; Equal Loads
Benign
Triple Outputs
570
Thousand Hours,
o
75 mV; p-p, Nom.Line FL,
20Mhz B.W. using
+25 C, Ground
Benign
1 μf bypass capacitor
% of Vout
Continuous, Auto-
matic Recovery
12V and 15V Outputs
Short Circuit Protection
1
1
2
3
= Output voltage at nominal line & FL
Transient Recovery Time
100 μS to within1% error
band for 50% step
load change
0.01 % per C
See Model Selection Guide
= % Output voltage measured from min. input line to maximum
= Output voltage measured from FL to 10% Load
o
Temperature Coefficient
Over Voltage Protection