Power Entry Modules with Line Filter
DD12
https://www.schurter.com /PG06
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole
Screw-on mounting horizontal (version B)
Order required accessories separately
Screw-on mounting vertical (version A)
Snap-in mounting
C14
See below:
Approvals and Compliances
70° C
Description
Characteristics
- Panel mount :
- Ultra-compact design. Ideal for low profile designs
Aluminum case provides good shielding
- All single elements are already wired
Screw-on from front side
- 4 Functions :
- Fuse drawer meets requirements of medical standard IEC/EN 60601-1
- Ideal for application with high transient loads
- Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for
fuse-links 5 x 20 mm 1- or 2-pole , Line filter in standard and medical
version
- V-Lock notch standard
- Quick connect terminals 6.3 x 0.8 mm
Other versions on request
- Solder terminals
- Fuse drawer 1-pole, plus spare fuse case
- Fuse drawer 2-pole, with shorting bar
- Other rocker marking
- Line switch, illuminated
- Line switch 1-pole
Unique Selling Proposition
- Various mounting options
- Attractive flat design
- Switch for highest inrush current
- V-Lock cord retaining
- Medical version M80
- Class X1- and Y1-capacitors for enhanced withstand voltage
References
Alternative: version without line filter DD11
Alternative: version for snap-in mounting KMF
Alternative: version with 2-stage filter DD14
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Landing Page
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
1 - 10A @ Ta 40 °C / 250VAC; 50Hz
1 - 8A @ Ta 40 °C / 250VAC; 60Hz
standard < 0.5mA (250V / 60Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7kVDC between L-N
appliance inlet/-outlet
Fuseholder
C14 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
Dielectric Strength
> 2.7kVDC between L/N-PE
Test voltage (2sec)
for fuse-links 5 x 20mm
Rated Power Acceptance @
Ta 23 °C
5 x 20: 2W (1 pole)/ 1.6W (2-pole) per
pole
Allowable Operation Tempe-
rature
-25°C to 85°C
Power Acceptance @ Ta >
23°C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Climatic Category
IP-Protection
Protection Class
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on mounting: max 8mm
Mounting screw torque max 0.5Nm
Snap-in: 1mm to 3mm
Line Switch
Line Filter
MTBF
Terminal
Panel Thickness S
Technical Details
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
Material: Housing
Thermoplastic, black, UL 94V-0
> 2'000'000h acc. to MIL-HB-217 F
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
1
EMC Products