Features
!
High Temperature Operation, up to 110°C Case
with No Derating
!
Fully Self Contained, No External Parts Required
for Operation, Ultra Low Input Reflected Ripple
!
Fixed Frequency Design
!
Low and Specified Input/Output Capacitance
!
Overcurrent Protected for Long, Reliable Operation
!
Five-sided Shielding
!
Water Washable Case Design
!
Five Year Warranty
Description
Selection Chart
The 24S5.2000CD DC/DC converter is designed for fast
integration with your system’s power needs. With no external
components or filtering necessary for all but the most critical
applications, these converters can provide power instantly.
This saves you costly engineering time required to design
your system around the power converter.
Input Range
VDC
Output
VDC
Output
mA
Model
Min
Max
24S5.2000CD
18
36
5
2000
Output Parameters*
Model
24S5.2000CD
Units
Input Parameters*
Output Voltage
5
VDC
Model
24S5.2000CD
Units
MIN
TYP
MAX
4.90
5.00
5.10
MIN
MAX
18
36
Output Voltage Accuracy
VDC
A
Voltage Range
VDC
mA P-P
mA
Reflected Ripple (2)
TYP
20
MIN
MAX
0.0
2.0
Rated Load Range
Input Current Full Load
No Load
TYP
TYP
495
7
Load Regulation
25% Max Load -
Max Load
TYP
MAX
0.2
0.4
Efficiency
TYP
TYP
84
%
%
Switching Frequency
220
kHz
Maximum Input
Overvoltage,
100ms Maximum
Turn-on Time,
1% Output Error
Line Regulation
Vin = Min-Max VDC
TYP
MAX
0.03
0.2
MAX
TYP
45
VDC
%
Short Term Stability (5)
Transient Response (6)
Dynamic Response (7)
Input Ripple Rejection (8) TYP
Noise, Peak - Peak (2)
TYP
TYP
TYP
< 0.05
250
90
> 40
70
%/24Hrs
µs
mV peak
dB
6
ms
Recommended Fuse
(3)
AMPS
TYPA
mV P-P
TYP
50
150
Temperature Coefficient
ppm/°C
MAX
Short Circuit Protection to
Common
Continuous, Current Limit
Protection
NOTES
AllparametersmeasuredatTc=25°C,nominalinputvoltage
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
(6) The transient response is specified as the time required to settle
from a 50 to 75 % step load change (rise time of step = 2 µSec)
to a 1% error band.
*
(7) Dynamic response is the peak overshoot during a transient
as defined in note 6 above.
(2) Noise is measured per CALEX Application Notes. Measurement
bandwidth is 0-20 MHz for peak-peak measurements, 10 kHz to
1 MHz for RMS measurements. Output noise is measured with
a 0.01µF / 100V ceramic capacitor in parallel with a 1µf / 35V
Tantalum capacitor across output pins. Input reflected ripple
is measured into a 10µH source impedance.
(8) The input ripple rejection is specified for DC to 120 Hz ripple with
a modulation amplitude of 1% of Vin.
(9) Thecasethermalimpedanceisspecifiedasthecasetemperature
rise over ambient per package watt dissipated.
(10) Specifications subject to change without notice.
(3) To determine the correct fuse size, see CALEX Application
Notes.
(4) The Case is tied to the -input pin.
(5) Short term stability is specified after a 30 minute warmup at full
load, constant line and recording the drift over a 24 hour period.
2401 Stanwell Drive
•
Concord, California 94520
•
Ph: 925/687-4411 or 800/542-3355
•
Fax: 925/687-3333
•
www.calex.com
•