描述
Direct-Wire Photoelectronic Smoke Detector

2400A 数据手册

 浏览型号2400A的Datasheet PDF文件第2页浏览型号2400A的Datasheet PDF文件第3页浏览型号2400A的Datasheet PDF文件第4页 
400 Series™  
Direct-Wire Photoelectronic  
Smoke Detector  
A Division of Pittway  
3825 Ohio Avenue, St. Charles, IL 60174  
1-800-SENSOR2 (736-7672), Fax 630-377-6495  
http://www.systemsensor.com  
Models Available  
2400/2400A Photoelectronic  
2400TH Photoelectronic with Thermal  
2412B/2412BA Photoelectronic  
2412THB Photoelectronic with Thermal  
2424 Photoelectronic  
2424TH Photoelectronic with Thermal  
Features  
• 12 or 24 volt operation  
• Field sensitivity metering of detector to meet NFPA 72  
requirements  
Twist-on mounting bracket with tamper option  
• SEMS screws for easy wiring  
• Unique optical sensing chamber  
• Removable cover and insect screen for easy  
cleaning  
• Visible LED blinks in standby, latches on in  
alarm  
• 3-year warranty  
• Optional built-in 135°F (57°C) heat sensor  
• Sealed against dirt, insects, and back pressure  
Specifications  
Size:  
3.2(8.1 cm) h, 5.5(13.9 cm)  
Sensitivity:  
3.0% ± .7 ft. nominal  
dia. with mounting bracket;  
add .5(1.27 cm) to height for  
thermal  
Test Features:  
1. Test port – Insert 0.1 inch maximum diameter allen  
wrench or screwdriver into test port on detector  
housing.  
Shipping Weight:  
0.5 lb. (227 g)  
Operating Temperature Range:  
2. Test card – After removing detector cover, insert  
calibrated test card into test slot on screen.  
3. Test module – Using a standard voltmeter interface,  
insert MOD400R plug into detector’s module port.  
Fulfills calibrated sensitivity test per NFPA 72.  
Thermal Sensor Rating  
Thermal Models:  
All Other Models:  
32°F to 100°F (0°C to 38°C)  
32°F to 120°F (0°C to 49°C)  
Operating  
Humidity Range:  
Air Velocity Rating:  
Wiring Gauge:  
10 – 93% RH noncondensing  
3000 fpm  
12 – 18 AWG, twisted pair  
recommended  
(thermal models only): 135°F fixed temperature  
restorable  
Mounting:  
31/  
or 4octagon box,  
2
4square box with plaster ring,  
50, 60, 75 mm boxes  
Smoke Detector Spacing:  
On smooth ceilings (as defined in NFPA 72), spacing  
of 30 feet (900 sq. ft.) may be used as a guide. Other  
spacing may be used depending on ceiling height,  
high air movements, and other conditions or response  
requirements.  
APPROVED  
© System Sensor 2/97  
This document is not intended to be used for installation purposes.  
A05-194-03  

与2400A相关器件

型号 品牌 获取价格 描述 数据表
2400AIT SYSTEMSENSOR

获取价格

Direct Wire Photoelectronic with Fixed Heat Smoke Detectors
2400AT SYSTEMSENSOR

获取价格

Direct Wire Photoelectronic with Fixed Heat Smoke Detectors
2400DP39A5425 JOHANSON

获取价格

2450 / 5400 MHz Diplexer ( BPF / BPF)
2400LP18A0200 JOHANSON

获取价格

2.4 GHz Low Pass Filter
2400LP18A0200E JOHANSON

获取价格

2400 MHz, CERAMIC LPF, CERAMIC PACKAGE-4
2400T GAMEWELL-FCI

获取价格

Photoelectronic Detector
2400TH SYSTEMSENSOR

获取价格

Direct-Wire Photoelectronic Smoke Detector
2401 POMONA

获取价格

Size A Aluminum Box With Cover BNC TEE F-F-M
2401 KR

获取价格

Surface Mount Diplexer
2401.0/100 ALTECH

获取价格

Connector Accessory,