Max. 1220 m3/h
DC axial fans
220 x 200 x 51 mm
–
Possible special versions:
(See chapter DC fans - specials)
- Speed signal
–
Material:
Housing: Die-cast aluminum
Impeller: GRP1) (PA)
–
–
Direction of air flow: Exhaust over struts
Direction of rotation: Counterclockwise,
looking towards rotor
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Multi-option control input
- Moisture protection
–
–
Connection:
Via single wires AWG 18, 20 or
AWG 22, TR 64, speed signal
and control input AWG 22
Highly efficient and smoothly
operating 3-phase fan drive
Housing with grounding lug
for screw M4 x 8 (Torx)
1000 g
Highlights:
- Salt spray protection
- Degree of protection: IP 54
–
Weight:
1) Fiberglass-reinforced plastic
Series 2200 FTD
Nominal data
Type
m3/h
cfm
VDC
VDC
dB(A) Bel(A)
/
Watts
rpm-1
°C
Hours
Hours
2214 F/2 TDHO
2214 F/2 TDHHO
790
940
465
553
24
24
16...30
16...36
62
66
7.1
7.4
35
48
4250
5000
-20...+75
-20...+70
90 000 / 42 500 152 500
85 000 / 42 500 142 500
¿
¡
2218 F/2 TDHO
2218 F/2 TDHHO
790
940
465
553
718
48
48
48
36...57
36...72
36...72
62
66
72
7.1
7.4
8.2
35
48
4250
5000
6500
-20...+75
-20...+70
-20...+65
90 000 / 42 500 152 500
85 000 / 42 500 142 500
70 000 / 40 000 117 500
¿
¡
¬
2218 F/2 TDH4P
1220
103
Subject to change
Speed control range from 1000 rpm-1 up to maximum nominal speed.
Standstill at 0% PWM, Type O: standstill if control wire is interrupted; Type P: maximum speed if control wire is interrupted.
* Power consumption at free air flow. These values can be significantly higher in the operating point.
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L A ISO 103002
W
measured on a hemisphere with a radius of 2 m.
Sound pressure level L A measured at 1 m distance from
p
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Finger guards
from p. 242
81