5秒后页面跳转
213843-1 PDF预览

213843-1

更新时间: 2024-11-02 01:10:27
品牌 Logo 应用领域
泰科 - TE 连接器连接器支架
页数 文件大小 规格书
2页 213K
描述
Extraction Tools

213843-1 技术参数

是否Rohs认证: 符合生命周期:Active
Reach Compliance Code:compliantECCN代码:EAR99
HTS代码:8536.90.40.00Factory Lead Time:3 weeks
风险等级:5.6组装件名称:CONTACT
连接器支架类型:CONNECTOR ACCESSORY触点性别:FEMALE
DIN 符合性:NO设计用途:POWER
IEC 符合性:NOMIL 符合性:NO
材料:COPPER安装方式:STRAIGHT
端子类型:CRIMPBase Number Matches:1

213843-1 数据手册

 浏览型号213843-1的Datasheet PDF文件第2页 
Instruction Sheet  
Extraction Tools  
318813-1 and 318813-3  
408-4374  
16 FEB 15 Rev B  
Interlock Lever  
Plastic Handle  
Spring-Loaded  
Metal Tip  
Figure 1  
1. INTRODUCTION  
Extraction Tool 318813-1, shown in Figure 1, is designed to remove the Size 8 straight and right-angle coaxial  
contacts and AMPLIMITE* power contacts and .125 POWERBAND* contacts listed in Figure 2 from connector  
housings. Read these instructions thoroughly before attempting to remove any contacts. Tool 318813-3 is  
designed for the Extended POWERBAND Pin contacts.  
CONTACT BASE PART NUMBER  
COAXIAL  
POWER  
211159-1  
212013-1  
212014-1  
213841-1  
213843-1  
213845-1  
213847-1  
211159-2  
211161-1  
211161-2  
212007-1  
212008-1  
228596-1  
228604-1  
228618-1  
Figure 2  
2. DESCRIPTION (Figure 1)  
The extraction tool consists of a spring-loaded metal tip with an integral plunger mounted to a plastic handle  
with an interlock lever. When the interlock lever is depressed, the plunger is held until the contact locking  
lances are depressed by the tip.  
After the lever is released, the plunger is released, permitting the contact to be pushed out the rear of the  
housing.  
3. EXTRACTION PROCEDURE (Figure 3)  
NOTE  
Before extracting coaxial contacts, use a small, sharp tool to remove the nylon alignment ring from the front of the contact.  
1. Determine the contact to be removed and grasp the wire attached to that contact.  
2. Move the contact forward as far as possible by pushing the wire toward the housing.  
3. Depress the extraction tool interlock lever and insert the tip of the tool into the contact cavity in the  
mating face of the housing. Make sure that the tip is completely bottomed in the cavity.  
4. While holding the tool in position, release the interlock lever, then push the handle until the contact  
backs out of the rear of the housing. The wire and contact should pull out of the housing.  
This controlled document is subject to change.  
For latest revision and Regional Customer Service,  
visit our website at www.te.com.  
© 2015 TE Connectivity family of companies  
All Rights Reserved  
*Trademark  
TOOLING ASSISTANCE CENTER 1-800-722-1111  
PRODUCT INFORMATION 1-800-522-6752  
1 of 2  
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.  

与213843-1相关器件

型号 品牌 获取价格 描述 数据表
213845-1 TE

获取价格

Extraction Tools
213847-1 TE

获取价格

Extraction Tools
213848-1 MACOM

获取价格

AMP Circular Connectors for Commercial Signal and Power Applications
213849-1 MACOM

获取价格

AMP Circular Connectors for Commercial Signal and Power Applications
213850-1 MACOM

获取价格

AMP Circular Connectors for Commercial Signal and Power Applications
213851-1 MACOM

获取价格

AMP Circular Connectors for Commercial Signal and Power Applications
213852-1 MACOM

获取价格

AMP Circular Connectors for Commercial Signal and Power Applications
213853-1 MACOM

获取价格

AMP Circular Connectors for Commercial Signal and Power Applications
213860-1 MACOM

获取价格

AMP Circular Connectors for Commercial Signal and Power Applications
2138601635 MOLEX

获取价格

NTC Ring Temperature Sensor-to-Micro-Lock Plu