Features
Applications
■ Balanced Mini-TRIGARD™
■ 5 mm diameter, 7.5 mm long
■ UL Recognized
■ Telecommunications
■ Industrial electronics
■ Commercial electronics
■ Consumer electronics
■ Automotive, aircraft, military electronics
■ RoHS compliant* versions available
2036 Series - Miniature 3-Pole Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31
Model No.
Characteristic
2036-07
2036-09
2036-15
2036-20
2036-23
2036-25
DC Sparkover 2ꢀ ꢁ @ 1ꢀꢀ V/s
75 V
9ꢀ V
15ꢀ V
2ꢀꢀ V
23ꢀ V
25ꢀV
Impulse Sparkover
1ꢀꢀ V/µs
25ꢀ V
525 V
25ꢀ V
55ꢀ V
35ꢀ V
5ꢀꢀ V
425 V
575 V
45ꢀ V
6ꢀꢀ V
475 V
625 V
1ꢀꢀꢀ V/µs
Model No.
Characteristic
2036-30
2036-35
2036-40
2036-42
2036-47
2036-60
DC Sparkover 2ꢀ ꢁ @ 1ꢀꢀ V/s
3ꢀꢀ V
35ꢀ V
4ꢀꢀ V
42ꢀ V
47ꢀ V
6ꢀꢀ V
Impulse Sparkover
1ꢀꢀ V/µs
5ꢀꢀ V
65ꢀ V
6ꢀꢀ V
75ꢀ V
65ꢀ V
825 V
675 V
85ꢀ V
75ꢀ V
95ꢀ V
85ꢀ V
11ꢀꢀ V
1ꢀꢀꢀ V/µs
Impulse Transverse Delay...................1ꢀꢀ V/µs ................................................................................. <75 ns
Insulation Resistance .........................1ꢀꢀ V (5ꢀ V for Model 2ꢀ36–ꢀ7 & 2ꢀ36-ꢀ9) ........................... >1ꢀ1ꢀ Ω
Glow Voltage ......................................1ꢀ mA..................................................................................... ~7ꢀ V
Arc Voltage .........................................1 A.......................................................................................... ~1ꢀ V
Glow-Arc Transition Current............................................................................................................... <ꢀ.5 A
Capacitance .......................................1 MHz..................................................................................... <2 pF
1
DC Holdover Voltage .......................135 V, (52 V for Model 2ꢀ36-ꢀ7 & 2ꢀ36-ꢀ9, ........................... <15ꢀ ms
8ꢀ V for Model 2ꢀ36-15)
2
Impulse Discharge Current.................2ꢀꢀꢀꢀ A, 8/2ꢀ µs .................................................................. 1 operation minimum
1ꢀꢀꢀꢀ A, 8/2ꢀ µs.................................................................... >1ꢀ operations
2ꢀꢀꢀ A, 1ꢀ/35ꢀ µs.................................................................. 1 operation
2ꢀꢀ A, 1ꢀ/1ꢀꢀꢀ µs ................................................................. >3ꢀꢀ operations
2ꢀꢀ A, 1ꢀ/7ꢀꢀ µs ................................................................... >5ꢀꢀ operations
2
Alternating Discharge Current............2ꢀ Arms, 1 s .......................................................................... 1 operation minimum
1ꢀ Arms, 1 s ........................................................................... >1ꢀ operations
Operating Temperature....................................................................................................................... -55 to +85 °C
Climatic Category (IEC 6ꢀꢀ68-1)........................................................................................................ 4ꢀ/9ꢀ/21
Optional Switch-Grade Fail-Short device available.
Notes:
• UL recognized component, UL File E153537.
• No model number marking on tube; date code and voltage only: month year digits, xxxV (e.g. ꢀ2ꢀ9 4ꢀꢀV).
• The rated discharge current for Mini-TRIGARD™ Gas Discharge Tubes is the total current equally divided between each line to
ground.
• Sparkover limits after life 25 ꢁ, IR >1ꢀ8Ω (-25 ꢁ,+3ꢀ ꢁ for Model 2ꢀ36-ꢀ7, 2ꢀ36-ꢀ9 and 2ꢀ36-6ꢀ).
• Operating characteristics per RUS PE-8ꢀ and Telcordia GR 1361 available, contact factory.
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL ꢀ.65 Level II, DIN ISO 2859.
1
Network applied.
2
DC Sparkover may exceed 25 ꢁ after discharge, but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.