Features
Applications
■ Bourns® FLAT® GDT technology
■ Flexible mounting options
■ Volume- and space-saving design
■ Improved impulse performance
■ 10 kA 8/20 µs rated
■ Telecom CPE
■ Industrial Communications
■ Surge Protective Devices
■ High density PCB assemblies
17-6
814
17-9
814
17-6
814
■
UL Recognized
■ RoHS compliant*
2017 Series Gas Discharge Tube Surge Arrestor with FLAT® Technology
Description
Bourns sets a new industry standard by offering this 2-electrode Gas Discharge Tube (GDT) in an innovative flat package design.
The Model 2017 Series with FLAT® Technology provides a volume and space-saving solution for high density and space-restricted
PCB applications. The series is offered in a leadless version for cartridge or clamp fit applications. Surface mount versions are
available in vertical and horizontal mounting configurations.
Characteristics
Test Methods per ITU-T (CCITT) K.12 Class 3 and IEC 61643-311
Model No.
Characteristic
2017-09
2017-15
2017-23
2017-35
2017-42
2017-50
(1)
DC Sparkover ±20 % @ 100 V/s
90 V
150 V
230 V
350 V
420 V
500 V
(2)
DC Sparkover End-of-Life Values
Maximum (99 % of values)
Minimum (99 % of values)
<120 V
>65 V
<195 V
>110 V
<300 V
>170 V
<455 V
>260 V
<550 V
>360 V
<650 V
>400 V
(3)
Impulse Sparkover Voltage
100 V/μs Typical /
For 99 % of Values
1 kV/μs Typical /
For 99 % of Values
350 / <450 V 400 / <550 V 450 / <600 V 600 / <750 V 700 / <850 V 750 / <950 V
600 / <800 V 600 / <850 V 700 / <950 V 800 / <1000 V 900 / <1050 V 950 / <1200 V
Insulation Resistance (IR) ..................100 V (50 V for Model 2017-09)............................................. >1 GΩ
Glow Voltage ......................................10 mA..................................................................................... ~70 V
Arc Voltage.........................................>1 A........................................................................................ ~10 V
Capacitance........................................1 MHz..................................................................................... <2.5 pF
Impulse Discharge Current.................12000 A, 8/20 μs .................................................................... 1 operation
10000 A, 8/20 μs .................................................................... >10 operations
2500 A, 10/350 μs .................................................................. 1 operation
100 A, 10/1000 μs ................................................................. >300 operations
10 A, 10/1000 μs ................................................................... >1500 operations
Alternating Discharge Current............10 Arms, 1 s ........................................................................... >10 operations
Operating Temperature....................................................................................................................... -55 to +105 °C
Storage Temperature.......................................................................................................................... -55 to +105 °C
Climatic Category (IEC 60068-1)........................................................................................................ 55/105/21
(4)
Pushover Strength
........................................................................................................................ 5 kg
Notes:
UL Recognized component, UL File E153537
(1)
(2)
(3)
(4)
In ionized mode.
At delivery AQL 0.65 Level II, DIN ISO 2859.
Pushover Strength test performed on a board-mounted Model 2017-xx-SMC (Vertical Mount).
IR after life >108 Ω.
How to Order
2017 - xx - xxx - RP LF
Asia-Pacific: Tel: +886-2 2562-4117 • Email: asiacus@bourns.com
Series Designator
2017 = 2-electrode GDT with FLAT®
EMEA: Tel: +36 88 520 390 • Email: eurocus@bourns.com
Technology, 10 kA 8/20 μs rated
The Americas: Tel: +1-951 781-5500 • Email: americus@bourns.com
Voltage (Divided by 10)
www.bourns.com
09 = 90 V
15 = 150 V
23 = 230 V
35 = 350 V
42 = 420 V
50 = 500 V
Configuration
A = No Leads, (Clamp-Cartridge)
SMH = Horizontal Mount SMD
SMC = Vertical Mount SMD
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/
EU June 8, 2011.
“FLAT” is a registered trademark of Bourns, Inc. in the U.S. and other countries.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different
applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.
Packaging
RP = Reelpack (Standard)
RoHS Compliancy
LF = RoHS Compliant Product