200QBW4_2.25 Series
200W Quarter-Brick - Single Output DC-DC Converter - Wide Input - Isolated & Regulated
DC-DC Converter
200 Watt
Wide Input voltage range (4:1)
High efficiency up to 94%
Short circuit protection (SCP)
Input under-voltage, over-
current, over–voltage, over-
temperature protection
Isolation: 2.25KVDC
Operating temperature range:
-40°C to +85°C
The 200QBW4_2.25 series offers 4:1 input voltage, efficiency up to 94%,
2250VDC isolation, Input under-voltage protection, output short circuit
protection, over-current protection, over–voltage protection, over-
temperature protection and EMI meets CISPR22/EN55022 CLASS B.
Five-sided metal shielding
package
International standard pin-out:
1/4 brick
All models are widely applied in battery power supplies, industrial
control, electricity, instruments, railway, communication fields.
Common specifications
Short circuit protection:
Cooling:
Output specifications
Hiccup, continuous, automatic recovery
Natural (20FLM) or forced convection
-40°C~+85°C
Item
Test condition
Min
Typ
1
Max
3
Units
%
Output voltage
accuracy
Operation temperature range:
Storage temperature range:
Over temperature protection:
Pin welding resistance temperature:
Storage humidity range:
Vibration:
Line regulation
Load regulation
0.2
0.5
0.5
%
-55°C ~+125°C
0.75
%
+95°C MIN / +105°C TYP / +115°C MAX
300°C MAX, 1.5mm from case for 10sec.
< 95%
Transient recovery
time
25% load step change
300
500
5
µs
Transient response
deviation
25% load step change
• 5V output
• others
3
%
IEC/EN61373 car body 1 B mold
90%Vo MIN, 110%Vo MAX
105%Vo MAX
Trim:
Temperature
coefficient
0.03 %/°C
Sense:
Case material:
Plastic [UL94-V0] / aluminium
500,000 hours
Ripple & Noise*
20MHz Bandwidth
150
130
250
mVp-p
%Vo
MTBF:
Output over-voltage Input voltage range
protection
110
110
160
Weight:
83g / 103g (with base-plate) /
114g (with heatsink)
Output over-current Input voltage range
protection
130
150
%Io
Switching frequency
PWM mode
250
KHz
Input specifications
*Test ripple and noise by “parallel cable” method.
Item
Test condition
Min Typ
4579/
Max
Units
mA
Input current
full load/no load
4682/
200
100
Reflected ripple
current
Nominal Vin and full
load
100
mA
Isolation specifications
Item
Test condition
Min
Typ
Max
Units
VDC
Surge voltage
1sec. max.
100% load
-0.7
14
90
18
VDC
VDC
Isolation voltage
Tested for 1 minute
and leak current less
than 5mA
2250
Start-up threshold
voltage
Input under
voltage protection
16
VDC
Isolation resistance
Insulation voltage
500VDC
100
MΩ
pF
Input filter
Hot plug
Pi Type
Isolation capaci-
tance
Input-output,
100KHz/0.1V
2200
Unavailable
Ctrl
• Module switch ON
Ctrl suspended or connected to
TTL high level (3.5-12VDC)
Ctrl pin connected to GND or low
level (0-1.2VDC)
(the voltage of Ctrl
pin is relative to input
pin GND)
• Module switch OFF
Example:
200QBW4_4805S2.25
• Input current when
switched OFF
2
10
mA
200= 200 Watt; QB= Quarter-Brick; W4= Wide input (4:1);
48= 18-75 Vin; 05= 5Vout; S= Single Output; 2.25= 2.25kVDC isolation
Note:
1. Operation under minimum load will not damage the converter; However, they
may not meet all specification listed, and that will reduce the life of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage
and rated output load unless otherwise specified.
3. In this datasheet, all the test methods of indications are based on corporate
standards.
Page 1 of 6
GAPTEC-Electronic GmbH & Co. KG
sales@gaptec-electronic.com – www.gaptec-electronic.com
200QBW4_2.25 – Rev. 2017-1.0
Specifications subject to change without notice.