Thermal Automotive Circuit Breaker 2-5200-...
Description
Single pole thermal circuit breaker with push-to-reset, tease-free,
trip-free, snap action mechanism (R-type TO CBE to EN 60934;
M-type when fitted with optional manual release feature). Designed
for plug-in mounting with E-T-A sockets 10 and 16.
Typical applications
Extra low voltage wiring systems and components.
1
Ordering information
2-5200-...
Type No.
2-5200 plug-in
Manual release (optional)
H
manual release facility
Current ratings
0.05...16 A
Technical data
For further details please see chapter: Technical Information
Voltage rating
DC 28 V
(UL: AC 250; DC 50 V)
2-5200 -H - 5 A
ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Current rating range
Typical life
0.05...16 A (up to 25 A to special order)
AC 250 V / DC 28 V:
0.05...16 A 5,000 operations at 2 x IN, inductive
Ambient temperature -20...+60 °C (-4...+140 °F)
Insulation co-ordination rated impulse pollution
Standard current ratings and typical internal resistance values
(IEC 60664 and 60664 A) withstand voltage
2.5 kV
degree
2
Current
rating (A)
Internal
Current
Internal
resistance (Ω)
resistance (Ω) rating (A)
Dielectric strength
(IEC 60664 and 60664A) test voltage
0.05
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
280
100
110
29
2.5
3
0.2
operating area
AC 1,500 V
Insulation resistance
Interrupting capacity Icn
> 100 MΩ (DC 500 V)
0.1
0.05...2.5 A
3...5 A
8 x IN
20 x IN
400 A
3,5
4
0.065
0.065
0.05
6...16 A
Interrupting capacity
(UL 1077)
UN
AC 250 V
DC 50 V
14
4.5
5
2,000 A
2,500 A
7
0.05
Degree of protection
(IEC 60529/DIN 40050)
operating area IP40
terminal area IP00
4.9
3.4
2.5
1.8
1.2
0.84
0.6
0.4
0.25
6
0.02
7
0.02
Vibration
Shock
8 g (57 to 500 Hz) 0.61 mm, (10-57 Hz),
to IEC 60068-2-6, test Fc,
8
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
25 g (11 ms)
to IEC 60068-2-27, test Ea
10
12
13
15
16
Corrosion
Humidity
Mass
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
1.2
1.5
1.8
2
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 35 g
Approvals
Authority
Standard
Rated voltage
Current ratings
UL
UL 1077
AC 250 V
DC 50 V
0.05 A…20 A
0.05 A…25 A
CSA
C22.2 No 235 AC 250 V
DC 50 V
0.05 A…20 A
0.05 A…25 A
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
1646
www.e-t-a.de
1