1W - Dual/Single Output - Wide Input - Isolated & Regulated
DC-DC Converter
DC-DC Converter
1 Watt
Wide 2:1 Input Voltage Range
High Efficiency up to 81%
1W Single and Dual outputs
I/O Isolation 2KVDC, 4KVDC
and 5,2KVDC
Operating Temperature
Range: -40°C to +100°C
Continuous Short Circuit
Protection (SCP)
The 1S8W_S & 1S8W_D series are specially designed for applications
where a wide range input voltage power supplies are isolated from the
input power supply in a distributed power supply system on a circuit
board.
Remote ON/OFF Control
These products apply to:
1) Where the voltage of the input power supply is wide range
(voltage range≤2:1)
2) Where isolation is necessary between input and output (isolation
voltage≤2000VDC/4000VDC/5200VDC)
3) Where the regulation of the output voltage and the output ripple
noise are demanded
Common specifications
Input filter:
Output specifications
Capacitor
Item
Test condition
Min
Typ
2
Max
Units
%
Output voltage
accuracy
Nominal Vin and full
load
Short circuit protection:
Temperature rise at full load:
Cooling:
Continuous
15°C TYP
Line regulation
Vin=min to max,full
load
0.5
0.5
%
Free air convection
-40°C~+100°C
Operation temperature range:
Operating case temperature:
Storage temperature range:
Storage humidity range:
Lead temperature range:
No-load power consumption:
Temperature coefficient:
Load regulation
20% to 100% full load
20MHz Bandwidth
%
110°C MAX
Output Ripple &
Noise
60
mVp-p
-55°C ~+125°C
Remote Power OFF
(leave open if not
used)
Device ON
open or
<0.8 VDC
< 95%
300°C MAX, 1.5mm from case for 10 sec
50mW TYP / 150mW MAX
(15 VDC max.)
Device OFF
Device OFF (Stand by
input current)
CTRL>1.5VDC
0.5mA max.
-40°C to +85°C ambient
0.015 %/°C TYP
Operating Frequency:
Case material:
150kHz MIN (optional typ. 200kHz)
Non-conductive black plastic [UL94-V0]
Epoxy [UL94-V0]
Example:
1S8W_0505S2RP
Potting material:
1=1Watt; S8= SIP8; W=wide input (2:1); 4,5 - 9Vin; 5Vout;
S= Single Output; 2= 2000VDC; R= Regulated Output
P= Short Circuit Protection
MTBF (MIL-HDBK 217F):
+25°C: 3650x103 hours
+85°C: 647x103 hours
Weight:
4.7g
Note:
Isolation specifications
1. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage
and rated output load unless otherwise specified.
2. In this datasheet, all the test methods of indications are based on corporate
standards.
Item
Test condition
Min
Typ
Max
Units
VDC
Isolation voltage
Tested for 1 minute
and 0,5mA max.
2000
4000
5200
Isolation resistance
500VDC, input to
output
15
GΩ
pF
Isolation capacitance
100KHz
30
Page 1 of 3
1S8W_2RP – Rev. 2019-1.2
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG