1N4933~1N4937
FAST RECOVERY PLASTIC RECTIFIER
Unit: inch(mm)
DO-41
50 to 600 Volts
VOLTAGE
FEATURES
CURRENT 1.0 Amperes
• High current capability.
.034(.86)
.028(.71)
• Plastic package has Underwriters Laboratory
Flammability Classification 94V-O utilizing
Flame Retardant Epoxy Molding Compound.
• Exceeds environmental standards of MIL-S-19500/228
• Fast Recovery for high efficiency.
• In compliance with EU RoHS 2002/95/EC directives
MECHANICALDATA
• Case: Molded plastic, DO-41
.107(2.7)
.080(2.0)
• Terminals: Axial leads, solderable to MIL-STD-750,Method 2026
• Polarity: Color Band denotes cathode end
• Mounting Position: Any
• Weight: 0.0118 ounce, 0.336 gram
MAXIMUMRATINGSANDELECTRICALCHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Resistive or inductive load, 60Hz.
PARAMETER
SYMBOL 1N4933 1N4934 1N4935 1N4936 1N4937 UNITS
Maximum Recurrent Peak Reverse Voltage
VR R M
VR M S
VD C
50
35
50
100
70
200
140
200
1.0
30
400
280
400
600
420
600
V
V
V
A
A
V
Maximum RMS Voltage
Maximum DC Blocking Voltage
100
Maximum Average Forward Current .375"(9.5mm)
IF ( A V )
IF S M
VF
lead length at TA =55O
C
Peak Forward Surge Current :8.3ms single half sine-wave
superimposed on rated load(JEDEC method)
Maximum Forward Voltage at 1.0A
1.2
Maximum DC Reverse Current at TJ=25O
Rated DC Blocking Voltage TJ=100O
C
5.0
500
µA
IR
C
Maximum Reverse Recovery Time (Note 1)
Typical Junction capacitance (Note 2)
tr r
CJ
200
ns
pF
12
41
Typical Junction Resistance(Note 3)
RθJA
O C / W
O C
Operating Junction and Storage Temperature Range
TJ ,TS T G
-55 to +150
NOTES:1. Reverse Recovery Test Conditions: IF=.5A, IR=1A, Irr=.25A
2. Measured at 1 MHz and applied reverse voltage of 4.0 VDC
3. Thermal resistance from junction to ambient and from junction to lead length 0.375"(9.5mm) P.C.B. mounted
PAGE . 1
STAD-MAR.03.2009
1