Small size - High voltage – High Capacitance
FEATURES
UPS – DC link – AC/DC motor controls – Power inverters
APPLICATIONS
Operating Temperature
Range
-40°C to +100°C
Above +85°C applied voltage must be de-rated by 1.5%/2.5%/°C (DC/AC)
+10% at 1 kHz, 25°C
+5% optional
Capacitance Tolerance
Code
A04
A03
A02
A06
A01
Surge Voltage
VDC
370
500
600
700
800
(VDC)
SVDC
470
A04
160
625
A03
250
750
A02
330
875
A06
380
1050
A01
400
Code
VAC
AC Voltage
(VAC)
Dissipation Factor (MAX)
Tan δ
C< 5μF
5μF<C<15μF
15μF<C<30μF
30μF<C<60μF C>60μF
.15 .17
at 1 kHz and 25°C
.06
.1
.13
See standard part listing, Applied RMS is to be de-rated at temperatures above 85°C. No
RMS current is to be applied when the ambient temperature is>+95°C
RMS Current
30000 MΩxuF
Insulation Resistance
After 1 minute of 100VDC applied between the terminals at 25°C
Self-Inductance
<1 nano-Henry per mm of lead spacing
Long Term Stability
Capacitance variation <1% MAX after 2 years
Terminal to Terminal
Terminal to case
Dielectric Strength
160% of VDC applied between the
terminals for 10 Seconds and 25°C
3KVAC at 50/60 Hz applied between the terminals
and case for 60 Seconds and 25°C
Failure Quota
300/billion component hours
100000/ 30000 hours (DC/AC)
∆C -3% MAX @ rated voltage
Life Expectancy
Test Condition
Performance requirements
Max Capacitance
change
Temperature= +40°C +2°C
< +2% of initially measured valued
Damp Heat Test
Relative Humidity=93 +2% DF Change
< 0.1% @ 1 kHz
Test length= 56 days
Max Capacitance change
DF Change
Insulation resistance
> 50% of minimum specified value
Resistance to soldering
Heat
Solder bath temperature: +260°C
+/- 5°C
Exposure time: 10 seconds +/- 1
second
<1% of initially measured value
< .1% at 1kHz
Insulation resistance
>50% of minimum specified value
Construction
Electrodes
Metallized Polypropylene film
Vacuum deposited Metal layers
Coating
Lead Terminations
Flame retardant Solvent resistant plastic case with epoxy end fill
Lead free tinned copper leads