Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
High Performance Compact Power Line Filter
RK Series
UL Recognized
CSA Certified
VDE Approved
1
RK Series
Specifications
• Compact
Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz:
@250 VAC 50 Hz:
0.16 mA
• Single stage
• Chassis mount
0.26 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
• Significant differential mode performance
• Suitable for industrial machinery
2250 VDC
1450 VDC
• Low input leakage current makes it suitable for
portable equipment
Rated Voltage (max):
250 VAC
50/60 Hz
3 to 20A
Operating Frequency:
Rated Current:
Operating Ambient Temperature Range
(at rated current I ):
-10°C to +40°C
In an ambient temperature (T ) higher than +40°C
r
a
Ordering Information
the maximum operating current (I ) is calculated as
o
follows: I = I (85-Ta)/45
o
r
10 E RK 1
Input / Output Style
1 – .250 [6.3] spade terminals
Electrical Schematic
RK Series
Leakage current designation
E – Low leakage (<0.5 mA)
LINE
LOAD
Current Rating
3, 6, 10, 15 or 20A
Available Part Numbers
3ERK1
10ERK1
20ERK1
6ERK1
15ERK1
65
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com