Bu s s m a n n
Ba t t e ry Dis c o n n e c t S w it c h
S e rie s 1 5 9 6 8
SPECIFICATIONS
Ratings: 50 VAC or VDC max; 400A continuous. Vehicle
cranking and max. surge currents to 2000A (based on
20% duty cycle with ON times of 5 seconds max.).
Operating Temperature: 300°F (150°C) max.
Storage Temperature: –40°F (–40°C) to 150°F (65°C).
Applications: A non-fused current interrupt
disconnect designed for opening the circuit between
a battery and the complete electrical load of a battery
powered system.
Options: Without mounting brackets — order Part No.
13969. For sealed version and other special options,
consult factory.
Dimensions:
4.87"
(123.8)
.59"
(15.1)
2.44"
(61.9)
3.12"
(79.4)
3.0"
(76.2)
3.5"
Ref. Point A
ON
OFF
(88.9)
4.19"
(106.4)
15968-1
3.00"
(76.2)
2.75"
(69.8)
Ref.
Point A
5.5"
(139.7)
Ref. Point A
15968-2
7.0"
.50"
(12.7)
(177.8)
1.25"
(31.7)
4.50"
8.0"
(203.2)
(114.3)
1.56"
(39.7)
ON
Ref. Point A
15968-3
3.81"
(96.8)
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any prod-
ucts and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it
should be tested by the user in all possible applications.
Form No. 15968
12-16-98
12-16-98
SB98107 Rev. A
Page 1 of 1
BIF Document: 2076