General Purpose
Panel/Plug-in Relays
SCHRACK
Power Relay RM C/D
n
1 pole 30/32 A, 1 form X, double make, NO or
1 form Z, double make + double break, NO + NC
Switching capacity up to 12800VA
DC or AC coil
n
n
n
n
Push-to-test button
Chassis mount
Typical applications
Battery chargers, heating control.
Z
Coil Data
Approvals
Coil voltage range
6 to 220 VDC
6 to 400 VAC
2
UL E214025, VDE Cert. No. 40003144 for AgNi-versions
Technical data of approved types on request.
Operative range, IEC 61810
Coil insulation system according UL
class 130 (B)
Contact Data
Contact arrangement
RMC
1 form Z,
1 NO + 1 NC
RMD
1 form X,
1 NO
Coil versions, DC coil
Rated voltage
Max. switching voltage
Rated current
Limiting making current, max. 20ms
Switching power
Contact material
400VAC
440VAC
30A/32A (VDE)
60A
Coil code
Rated
voltage
VDC
6
12
24
48
60
110
220
Coil
resistance
Ω 10ꢀ1)2)
32
110
475
2000
Rated coil
power
W
STD
LED
bipolar
L06
L12
L24
L48
L60
M10
N21
PD3)
LED+
PD3)
LA6
LB2
LC4
LE8
LG0
MB0
NC1
006
012
024
048
060
110
221
0A6
0B2
0C4
0E8
0G0
1B0
2C1
1.1
1.3
1.2
1.2
1.3
1.2
1.2
7500VA
AgCdO, AgNi 90/10
single bridging contact
24VDC/100mA
Contact style
Min. recommended contact load
Frequency of operation,
with/without load, DC coil
Operate/release time max., DC coil
Bounce time max., form A/form B, DC coil
2850
100001)
400002)
960/6000h-1
20/20ms
4/6ms
Operate voltage, DC coil
Release voltage, DC coil
1) Coil resistance 12ꢀ, 2) Coil resistance 15ꢀ.
75ꢀ of rated coil voltage
10ꢀ of rated coil voltage
3) Protection diode PD; standard polarity: +A1 / -A2.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Contact ratings
Type
EN 61810
RMC/D X of Z (NO), AgNi 32A, 400VAC res. 40°C
RMC Y of Z (NC), AgNi 32A, 400VAC res. 40°C
Contact
Load
Cycles
20x10³
10x10³
RMC/D X of Z (NO)
AgNi DC coil
RMC/D X of Z (NO)
30A, 400VAC res. 50°C
30A, 400VAC res. 40°C
10x10³
10x10³
AgNi AC coil
UL 508
RMC/D X/Y (NO/NC),
AgCdO,
RMC/D X/Y (NO/NC)
30 A, 277 VAC, general purpose 50°C 10x103
30 A, 415 VAC, resistive 50°C
10x103
10x103
6x103
RMC/D X (of Z / NO), AgNi 120 VAC, 0,75 HP 50°C
RMC/D X/Y (NO/NC)
Mechanical endurance
DC coil
240 VAC, 2 HP 50°C
10x106 operations
AC coil
10x106 operations
1
04-2015, Rev. 0415
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.