General Purpose Relays
PCB Relays
SCHRACK
Power PCB Relay RTH 105°C 16A
n
n
n
n
n
n
1 pole 16A, 1 form C (CO) or 1 form A (NO) contact
Ambient temperature 105°C
Sensitive coil 400mW
5kV/10mm coil-contact
Reinforced insulation
WG version: Product in accordance to IEC 60335-1
Typical applications
Oven control, cooking plate control
F0220-D
V Z b
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Coil Data
Coil voltage range
5 to 60VDC
90...110% URTD
class F
Operative range, IEC 61810
Coil insulation system according UL1446
Contact Data
Contact arrangement
1 form C (CO) or 1 form A (NO)
Coil versions, DC coil
Rated voltage
Max. switching voltage
Rated current
Limiting continuous current, form A/form B
Limiting making current (form A contact)
max. 4 s, duty factor 10 %
Breaking capacity max.
250VAC
400VAC
16A1)
Coil
code
Rated
voltage
VDC
9
12
24
Operate
voltage
VDC
6.3
8.4
Release
Coil
resistance
Ω 10%
203
360
1440
Rated coil
power
mW
voltage
VDC
0.9
1.2
2.4
16 / 26A
009
012
024
3991)
4001)
30A
4000VA
AgNi 90/10
360/72000h-1
8/6ms
16.8
4001)
1) Continuous thermal load > 10 A at 105°C requires reduction of coil power to 64% of
rated power after 100ms.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Contact material
Frequency of operation, with/without load
Operate/release time max.
Bounce time max., form A/form B
4/6ms
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
RTH14
RTH14
RTH14
RTH34
RTHH4
UL 508
RTH14
RTH34
A (NO)
C (CO)
B (NC)
A (NO)
A (NO)
10A, 250VAC resistive,105°C
16A, 250VAC resistive, 105°C
26A, 250VAC resistive, 85°C
10A, 400VAC resistive, 105°C
10A, 250VAC resistive, 105°C
150x103
10x103
500
150x103
250x103
A/B (NO/NC) 16A, 250VAC, resistive, 105°C
A (NO)
30x103
6x103
20A, 250VAC, general purpose, 105°C
Mechanical endurance
>30x106 operations
1) Continuous thermal load >10A at 105°C requires reduction of coil power to 64% of
rated power after 100ms
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
between contact and coil
Material group of insulation parts
Tracking index of relay base
1000Vrms
5000Vrms
≥10/10mm
IIIa
PTI250V
1
04-2011, Rev. 0411
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company