Thermal Overcurrent Circuit Breaker 1410-L1
Description
Single pole press-to-reset thermal circuit breaker with extremely fast
overload switching performance (R-type TO CBE to EN 60934).
Miniaturised construction minimises PCB real estate required.
PCB mounting or integral mounting. Largely temperature-insensitive.
Typical applications
Motors, transformers, solenoids, PCBs, hand-held machines, appliances,
instrumentation.
1
Ordering information
1410-L1...
Type No.
1410 single pole circuit breaker
Configuration
Technical data
L integral mounting or PCB mounting
Mounting
1 footprint 16.3x4.6
Number of poles
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 28 V
(UL: AC 250 V; DC 50 V)
1 1-pole, thermally protected
Hardware
Current rating range 1-2
Typical life
AC 240 V: 0.63...2.25 A 500 break operations at 2 x IN, inductive
2.5...10 A 500 break operations at 2 x IN, resistive
DC 50 V: 0.63...2.25 A 500 break operations at 2 x IN, inductive
DC 28 V: 2.5...10 A
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A) withstand voltage
2.5 kV
0.63...10 A
0
without
Terminal design
L1 solder pins 1.8x0.8 silver-plated
Characteristic curve
F1 fast acting
500 break operations at 2 x IN, inductive
Actuator, Type and Colour
S01
-20...+70 °C (-4...+158 °F)
reset button, black
Current ratings
0.63...10 A
rated impulse
pollution
degree
2
1410 - L 1 1 0 - L1 F1 - S01 - 0.8 A ordering example
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
*mounting hardware bulk shipped
operating area
AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Preferred types
Interrupting capacity Icn
(o-o-o)
0.63...2 A
2.5...8 A
10 A
12 x IN
8 x IN, AC max. 50 A
6 x IN, AC
Preferred types
Standard current ratings (A)
3.15...10 A
10 x IN, DC
0.63 0.8 1 1.5
2
2.5 3.15 4 5 6.3 8 10
Interrupting capacity
(UL 1077)
0.63...10 A
0.63...10 A
2,000 A
200 A
AC 250 V
DC 50 V
1410-L110-L1F1-
S01-
x
x
x
x
x
x
x
x
x
x
x
x
Degree of protection
(IEC 60529/DIN 40050)
operating area IP40
terminal area IP00
Vibration
8 g (57-500 Hz) 0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
Standard current ratings and typical internal resistance values
10 frequency cycles/axis
Shock
20 g (11 ms)
to IEC 60068-2-27, test Ea
Current
Internal
Current
Internal
rating (A)
resistance (Ω) rating (A)
resistance (Ω)
Corrosion
Humidity
Mass
48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
0.63
0.8
1
1.8
3.15
4
< 0.12
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
1.7
96 hours at 95 % RH
to IEC 60068-2-78, test Cab
1.3
5
approx. 5 g
1.5
1.8
2
< 1
6.3
8
< 1
< 1
10
Approvals
2.5
< 0.15
Authority
Standard
Rated voltage
Current ratings
VDE
IEC/EN 60934 AC 240 V
DC 50 V
0.63 A…6,3 A
0.63 A…2.25 A
2.5 A…10 A
DC 28 V
UL
UL 1077
AC 250 V
DC 50 V
0.63 A…10 A
0.63 A…10 A
CSA
C22.2 No 235
AC 125 V
DC 48 V
0.63 A…8 A
0.63 A…8 A
1651
www.e-t-a.de
1