Thermal Overcurrent Circuit Breaker 1410-F1...
Description
Miniaturised single pole rocker switch/thermal circuit breaker combining
ON/OFF switching and extremely fast overload performance in a
single component (S-type TO CBE to EN 60934/IEC 934). Under
overload conditions an internal neon (filament bulb for low voltages)
illuminates to give a clear signal of the tripped status of the mechanism
and thereby the cause of power interruption, suffix -B. Alternatively
the illumination can be conventionally wired to indicate the ON status
of the device, suffix -E. Returning the rocker switch through the
OFF position and back ON will reset the mechanism and restore the
supply. Largely temperature-insensitive. Complies with CBE standard
EN 60934 (IEC 60934).
1
Typical applications
1410-F1..
Motors, transformers, solenoids, PCBs, hand-held machines, appliances,
instrumentation.
Technical data
Voltage rating
AC 240 V; DC 28 V (DC 50 V upon request)
(UL: AC 250 V; DC 48 )
Ordering information
Current rating range
0.63...10 A
Type No.
1410 snap-in panel mounting type
Mounting
Typical life
circuit 1-3
30,000 operations for IN ≤ 6.3 A AC/DC
10,000 operations for IN > 6.3 A AC
3,000 operations for IN > 6.3 A DC
500 break operations at 2 x IN
F snap-in panel mounting
Size of frame
protection circuit 1-2
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A) withstand voltage
2.5 kV
1 to fit mounting cut-out 28 x 12.7 mm (1.1 x .5 in)
Number of poles
1 single pole, thermally protected
Accessories
-20...+70 °C (-4...+158 °F)
rated impulse
pollution
degree
2
0
without accessories
Terminal design
P1 blade terminals 2.8-0.8 (QC .110/2x.110) silver-plated
Characteristic curve
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
F1
fast acting
AC 3,000 V
Actuator style
W rocker, rounded profile
Actuator colour
14 red translucent
Actuator markings
Insulation resistance
Interrupting capacity Icn
> 100 MΩ (DC 500 V)
0.63...2 A
2.5...8 A
10 A
12 x IN
8 x IN, AC max. 50 A
6 x IN
Q
I and O
3.15...10 A 10 x IN, DC
Trip/ON illumination (optional)
B illuminated when tripped
E illuminated when ON
Illumination voltage range
(optional)
Interrupting capacity
(UL 1077)
0.63...10 A 2,000 A AC 250 V
0.63...8 A
0.63...5 A
200 A
200 A
DC 50 V
DC 60 V
Degree of protection
(IEC 60529/DIN 40050)
operating area IP30
terminal area IP00
2
3
4
20-28 V marked 24 V 35 mA
90-140 V marked 115 V < 1 mA
185-275 V marked 230 V < 1 mA
Current ratings
Vibration
8 g (57-500 Hz) 0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
0.63...10 A
Shock
20 g (11 ms)
to IEC 60068-2-27, test Ea
1410 - F 1 1 0 -P1 F1 - W 14 Q E 3 - 2 A
ordering example
Corrosion
Humidity
Mass
48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
96 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 9 g
Standard current ratings and typical internal resistance values
Current
rating (A)
Internal
Current
Internal
resistance (Ω)
Approvals
resistance (Ω) rating (A)
0.63
1
1.8
4
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
Authority
Standard
Rated voltage
Current ratings
1.3
5
UL
UL 1077
AC 250 V
DC 60 V
DC 50 V
0.63 A…10 A
0.63 A…5 A
5.5 A…8 A
1.5
2
< 1
6.3
8
< 1
2.5
3.15
< 0.15
< 0.12
10
CSA
C22.2 No 235
AC 125 V
DC 48 V
0,63 A…8 A
0,63 A…8 A
1651
www.e-t-a.de
1