M20S-03240A120, M20E-03240A120 | M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
Ordering information
A
B
C
D
E
F
System part
Sender
Type
Part no.
1018176
1018177
M20S-03240A120
M20E-03240A120
Receiver
1.) Concerns installation as a replacement part for previous type 2 device in machine: Regarding Machinery Directive
2006/42/EC, Article 1, Paragraph (2a) this type 2 device may only be used as a replacement part for identical PL d / SIL2
devices within the EU if the machine was put into circulation before 2015-05-10. Keep this note with your machine documen-
tation. If the machine is sold on, this note and the information it contains must be passed on to every subsequent buyer. 2.)
Concerns installation on new machines: Due to the amendment to the EN/IEC 61496-1 standard, this type 2 device may only
be installed on new machines up to PL c / SIL1 as of 2015-05-10.
Other models and accessories www.sick.com/M2000_Standard
Detailed technical data
Features
0 m ... 70 m, configurable
0 m ... 20 m
15 m ... 70 m
3
Scanning range
H
I
Low scanning range
Great scanning range
Number of beams
400 mm
Beam separation or resolution
Response time
8 ms
J
Optical synchronisation
Synchronization
Safety-related parameters
K
L
Type 2 (IEC 61496)
Type
SIL1 (IEC 61508)
SILCL1 (EN 62061)
Safety integrity level
Category 2 (EN ISO 13849)
13 /s (EN ISO 13849) 1)
Category
Test rate (internal test)
M
N
O
P
Q
R
S
T
≤ 8 min⁻¹ (EN ISO 13849) 2)
Maximum demand rate
Performance level
PL c (EN ISO 13849)
6.6 x 10-9 (EN ISO 13849)
PFHD (mean probability of a dangerous fail-
ure per hour)
20 years (EN ISO 13849)
TM (mission time)
At least one OSSD is in the OFF state.
Safe state in the event of a fault
1)
Internal test. The test rate may not be exceeded if an external test is performed.
2)
Between two requirements on a safety-related response of the device, at least 100 internal or external tests must be carried out.
Functions
Functions
Delivery status
✔
✔
Uncoded
Beam coding
Configurable scanning range
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-06-14 08:06:28
Subject to change without notice